Air Cleaner Outlet Pipe




Air Cleaner Outlet Pipe

1. Disconnect the crankcase ventilation tube and vacuum tube from the Air Cleaner (ACL) outlet pipe.

2. Loosen the 2 ACL outlet pipe clamps.
- Remove the ACL outlet pipe.

- To install, tighten to 3 Nm (27 lb-in).

3. To install, reverse the removal procedure.