Gauge Control Module Input Test
Gauge Control Module Input Test
1. Remove the gauge control module Service and Repair.
2. Disconnect connector A (30P) from the gauge control module.
3. Inspect the connector and socket terminals to be sure they are all making good contact.
- If the terminals are bent, loose or corroded, repair them as necessary, and recheck the system.
- If the terminals look OK, go to step 4.
4. Reconnect connector A to the gauge control module, and do these input tests at the following connector.
- If any test indicates a problem, find and correct the cause, then recheck the system.
- If all the input tests prove OK, replace the gauge control module.