Power Relay Test
Power Relay Test
Special Tools Required
- Relay Puller 07AAC-000A2A1 or 07AAC-000A1A0
Use this chart to identify the type of relay, then do the test listed for it.
NOTE: For the turn signal/hazard relay input test Turn Signal/Hazard Relay Input Test.
Normally-Open Four-Terminal Type
Check for continuity between the terminals.
- There should be continuity between terminals No. 1 and No. 2 when power is connected to terminal No. 4 and ground the terminal No. 3.
- There should be no continuity between terminals No. 1 and No. 2 when power is disconnected.
Resistance type
Diode type
Five-Terminal Type
Check for continuity between the terminals.
- There should be continuity between terminals No. 1 and No. 2 when power is connected to terminal No. 5 and ground the terminal No. 3.
- There should be continuity between terminals No. 1 and No. 4 when power is disconnected.
Resistance type
Diode type