Canister Vent Valve: Service and Repair
Evaporative Emission Canister Vent Solenoid Valve Replacement
Removal Procedure
Warning: Refer to Battery Disconnect Warning (Battery Disconnect Warning).
1. Disconnect the battery negative cable. Refer to Battery Negative Cable Disconnection and Connection (Service and Repair).
2. Disconnect the EVAP canister vent solenoid valve connector.
3. Disconnect the EVAP canister vent hose.
4. Remove the EVAP canister vent assembly (1) pushing it to the left side.
Installation Procedure
1. Install the EVAP canister vent assembly (1) pushing it to the right side.
2. Connect the EVAP canister vent hose.
3. Connect the EVAP canister vent solenoid valve connector.
4. Connect the battery negative cable. Refer to Battery Negative Cable Disconnection and Connection (Service and Repair).