Canister Purge Solenoid: Service and Repair
Evaporative Emission Canister Purge Solenoid Valve Replacement
Removal Procedure
1. Remove the air cleaner outlet duct. Refer to Air Cleaner Outlet Duct Replacement (Air Cleaner Outlet Duct Replacement).
2. Remove the generator battery control module cover, if necessary. Refer to Generator Control Module Cover Replacement ().
3. Disconnect the engine wiring harness electrical connector (1) from the evaporative emission (EVAP) canister purge solenoid valve (2).
4. Disconnect the chassis EVAP line quick connect fitting (2) from the EVAP canister purge solenoid valve. Refer to Plastic Collar Quick Connect Fitting Service (Plastic Collar Quick Connect Fitting Service).
5. Disconnect the engine EVAP line (1) quick connect fitting from the EVAP canister purge solenoid valve. Refer to Plastic Collar Quick Connect Fitting Service (Plastic Collar Quick Connect Fitting Service).
6. Remove the EVAP canister purge valve bracket bolt.
7. Remove the EVAP canister purge valve with bracket.
8. Remove the EVAP canister purge valve from the bracket.
9. Inspect for carbon release in the EVAP canister purge valve ports. If there is any loose carbon, replace the EVAP canister and any components necessary to remove the carbon particles.
Installation Procedure
1. Install the EVAP canister purge valve to the bracket.
2. Position the EVAP canister purge valve with bracket to the cylinder head.
Caution: Refer to Fastener Caution (Fastener Caution).
3. Install the EVAP canister purge valve bracket bolt and tighten to 25 Nm (18 lb ft).
4. Connect the engine EVAP line (1) quick connect fitting to the EVAP canister purge solenoid valve. Refer to Plastic Collar Quick Connect Fitting Service (Plastic Collar Quick Connect Fitting Service).
5. Connect the chassis EVAP line quick connect fitting (2) to the EVAP canister purge solenoid valve. Refer to Plastic Collar Quick Connect Fitting Service (Plastic Collar Quick Connect Fitting Service).
6. Connect the engine wiring harness electrical connector (1) to the EVAP canister purge solenoid valve (2).
7. Install the generator battery control module cover, if necessary. Refer to Generator Control Module Cover Replacement ().
8. Install the air cleaner outlet duct. Refer to Air Cleaner Outlet Duct Replacement (Air Cleaner Outlet Duct Replacement).