P0A90-251
P112 HYBRID VEHICLE CONTROL: HYBRID CONTROL SYSTEM: P0A90-251: Drive Motor "A" Performance
DTC P0A90-251 - Drive Motor "A" Performance
DESCRIPTION
When three-phase alternating current flows through the three-phase windings of the stator coil, a rotating magnetic field is generated in the motor. The system controls the rotating magnetic field in accordance with the rotating position and speed of the rotor. As a result, the permanent magnets provided on the rotor are pulled in the rotating direction, which cause the generation of torque.
The generated torque is practically proportionate to the amount of current. Therefore, the system controls the speed of the motor by regulating the frequency of the alternating current. Furthermore, the system properly controls the rotating magnetic field and the angle of the rotor magnets in order to generate high torque in an efficient manner, even at high speeds.
MONITOR DESCRIPTION
The HV control ECU monitors the hybrid vehicle motor (MG2). If the HV control ECU detects a reduction in the magnetic force of the MG2 or an in-phase short, it interprets this as a MG2 failure. The HV control ECU then illuminates the MIL and sets a DTC.
MONITOR STRATEGY
TYPICAL ENABLING CONDITIONS
TYPICAL MALFUNCTION THRESHOLDS
COMPONENT OPERATING RANGE
INSPECTION PROCEDURE
PROCEDURE
1. READ OUTPUT DTC (HV ECU)
(a) Connect the Techstream to the DLC3.
(b) Turn the power switch ON (IG).
(c) Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
(d) Check if DTCs are output.
Result:
DTC P0A90 (INF 251) and other DTCs are output
HINT: If any other codes besides P0A90 (INF 251) are output, perform troubleshooting for those DTCs first.
YES -- GO TO RELEVANT DTC CHART
NO -- REPLACE HYBRID VEHICLE MOTOR ASSEMBLY