Power Window Can Be Operated After Ignition Switch Is Turned Off Even If Operative Conditions Are Not Met
WINDSHIELD / WINDOWGLASS: POWER WINDOW CONTROL SYSTEM (for Convertible): Power Window can be Operated After Ignition Switch is Turned OFF Even if Operative Conditions are not Met
Power Window can be Operated After Ignition Switch is Turned OFF Even if Operative Conditions are not Met
DESCRIPTION
The multiplex network body ECU keeps power supplied to the power window regulator master switch and the regulator switch for 43 seconds after the ignition switch is turned OFF. However, the body ECU will cut power to the master switch if: 1) either front door is opened within 43 seconds, 2) a signal from any door courtesy light switches is input to the ECU within 43 seconds, or 3) no power window activity occurs within 43 seconds.
WIRING DIAGRAM
INSPECTION PROCEDURE
PROCEDURE
1. CHECK OPERATION FUNCTION AFTER IGNITION SWITCH IS TURNED OFF
(a) Check the power window operation function after the ignition switch is turned OFF.
Result:
B -- REPLACE POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY
A -- Continue to next step.
2. INSPECT FRONT DOOR COURTESY LIGHT SWITCH ASSEMBLY
NG -- REPLACE FRONT DOOR COURTESY LIGHT SWITCH ASSEMBLY
OK -- Continue to next step.
3. CHECK AND REPLACE WIRE HARNESS (COURTESY LIGHT SWITCH - MULTIPLEX NETWORK BODY ECU)
(a) Disconnect the D5 and D6 switch connectors.
(b) Disconnect the B7 and B8 ECU connectors.
(c) Measure the resistance of the wire harness side connectors.
Standard resistance:
NG -- REPAIR OR REPLACE HARNESS AND CONNECTOR
OK -- REPLACE MULTIPLEX NETWORK BODY ECU