Installation [12/2019 - ]: Procedure
WARNING: This page is about a different variant/trim than selected.
- INSTALL MOTOR CABLE WARNING:
Be sure to wear insulated gloves.
- Using an insulated tool, install the motor cable to the hybrid vehicle transaxle assembly with the 6 bolts.
Torque: 10 N.m (102 kgf/cm, 7 ft.lbf)
NOTE:- Keep the motor cable terminals and their installation area free from foreign matter, water, etc.
- Do not touch the waterproof seal or terminals of the motor cable.
- To prevent the motor cable from contacting the hybrid vehicle transaxle assembly, make sure that the inverter with converter assembly side of the motor cable is wrapped with a plastic bag or equivalent until directly before reconnection.
- Engage the 2 claws to install a new terminal cap to the hybrid vehicle transaxle assembly.NOTE:
- Keep the terminal cap and its installation area free from foreign matter, water, etc.
- Do not pinch the O-ring.
- Check that the terminal cap is securely installed.
- Temporarily install the connector cover to the hybrid vehicle transaxle assembly with the 2 bolts.
- Tighten the 2 bolts to install the connector cover.
Torque: 10 N.m (102 kgf/cm, 7 ft.lbf)
- Using an insulated tool, install the motor cable to the hybrid vehicle transaxle assembly with the 6 bolts.
- INSTALL INVERTER WITH CONVERTER ASSEMBLY
Refer to INSTALLATION [12/2019 - 11/2023] , or refer to INSTALLATION [11/2023 - ]