Inspection [12/2019 - ]: Procedure
WARNING: This page is about a different variant/trim than selected.
- INSPECT SHIFT LEVER POSITION SENSOR
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 7 (+B) - 3 (PR) Shift lever in P Below 1 Ω 7 (+B) - 4 (PNB) Below 1 Ω 7 (+B) - 8 (P) Below 1 Ω 7 (+B) - 1 (DB1), 2 (N), 6 (DB2) or 9 (R) Shift lever in P 10 kΩ or higher 7 (+B) - 3 (PR) Shift lever in R Below 1 Ω 7 (+B) - 9 (R) Below 1 Ω 7 (+B) - 1 (DB1), 2 (N), 4 (PNB), 6 (DB2) or 8 (P) Shift lever in R 10 kΩ or higher 7 (+B) - 2 (N) Shift lever in N Below 1 Ω 7 (+B) - 4 (PNB) Below 1 Ω 7 (+B) - 1 (DB1), 3 (PR), 6 (DB2), 8 (P) or 9 (R) Shift lever in N 10 kΩ or higher 7 (+B) - 1 (DB1) Shift lever in D or S Below 1 Ω 7 (+B) - 6 (DB2) Below 1 Ω 7 (+B) - 2 (N), 3 (PR), 4 (PNB), 8 (P) or 9 (R) Shift lever in D or S 10 kΩ or higher *a Component without harness connected
(Shift Lever Position Sensor)HINT:
The shift lever position sensor connector (shift lever position sensor side) does not have a terminal 5.
If the result is not as specified, replace the shift lever position sensor.