On-Vehicle Inspection [12/2019 - 11/2023]: Procedure
WARNING: This page is about a different variant/trim than selected.
- INSPECT OIL PUMP MOTOR RELAY
- Measure the resistance according to the value(s) in the table below.
*1 Oil Pump Motor Relay Standard Resistance
Tester Connection Condition Specified Condition 3 - 5 Auxiliary battery voltage not applied between terminals 1 and 2 10 kΩ or higher Auxiliary battery voltage applied between terminals 1 and 2 Below 1 Ω If the result is not as specified, replace the oil pump motor relay.
- Measure the resistance according to the value(s) in the table below.