DTC B1412: Ambient Temperature Sensor Circuit [12/2019 - 10/2022]: Procedure
- READ VALUE USING GTS (AMBIENT TEMP SENSOR)
- Read the Data List according to the display on the GTS.
Body Electrical > Air Conditioner > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note Ambient Temp Sensor Ambient temp. sensor (thermistor assembly) Min.: -23.30°C (-9.94°F)
Max.: 65.95°C (150.71°F)Actual ambient temperature displayed Ambient temp. sensor (thermistor assembly) circuit malfunction - When open circuit: -23.30°C (-9.94°F)
- When short circuit: 65.95°C (150.71°F)
Body Electrical > Air Conditioner > Data List
Tester Display Ambient Temp Sensor OK
The display is as specified in the normal condition column.
Result
Proceed to OK NG
Result:
OK
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY. Refer to REMOVAL [12/2019 - 10/2022]
Result:
NG
See step 2
- Read the Data List according to the display on the GTS.
- INSPECT AMBIENT TEMP. SENSOR (THERMISTOR ASSEMBLY)
Refer to INSPECTION [12/2019 - ]
Result
Proceed to OK NG Result:
NG
REPLACE AMBIENT TEMP. SENSOR (THERMISTOR ASSEMBLY). Refer to REMOVAL [12/2019 - 09/2020] , or refer to REMOVAL [09/2020 - 10/2021] , or refer to REMOVAL [10/2021 - 11/2023]
Result:
OK
See step 3
- CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - AMBIENT TEMP. SENSOR (THERMISTOR ASSEMBLY))
- Disconnect the H63 air conditioning amplifier assembly connector.
- Disconnect the A23 ambient temp. sensor (thermistor assembly) connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition H63-1 (TAM) - A23-2 Always Below 1 Ω H63-14 (SG-2) - A23-1 Always Below 1 Ω H63-1 (TAM) or A23-2 - Other terminals and body ground Always 10 kΩ or higher H63-14 (SG-2) or A23-1 - Other terminals and body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result:
OK
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY. Refer to REMOVAL [12/2019 - 10/2022]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR