On-Vehicle Inspection [12/2019 - 10/2022]: Procedure
- INSPECT NO. 1 ELECTRONIC FUEL INJECTION MAIN RELAY (EFI-MAIN)
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 3 - 5 Battery voltage not applied between terminals 1 and 2 10 kΩ or higher Battery voltage applied between terminals 1 and 2 Below 1 Ω If the result is not as specified, replace the No. 1 electronic fuel injection main relay (EFI-MAIN).
- Measure the resistance according to the value(s) in the table below.
- INSPECT AIR FUEL RATIO SENSOR HEATER RELAY (A/F HTR)
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 3 - 5 Battery voltage not applied between terminals 1 and 2 10 kΩ or higher Battery voltage applied between terminals 1 and 2 Below 1 Ω If the result is not as specified, replace the air fuel ratio sensor heater relay (A/F HTR).
- Measure the resistance according to the value(s) in the table below.
- INSPECT FUEL PUMP RELAY (FUEL PMP)
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 3 - 5 Battery voltage not applied between terminals 1 and 2 10 kΩ or higher Battery voltage applied between terminals 1 and 2 Below 1 Ω If the result is not as specified, replace the fuel pump relay (FUEL PMP).
- Measure the resistance according to the value(s) in the table below.
- INSPECT INJECTOR RELAY (D INJ)
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 3 - 5 Battery voltage not applied between terminals 1 and 2 10 kΩ or higher Battery voltage applied between terminals 1 and 2 Below 1 Ω If the result is not as specified, replace the injector relay (D INJ).
- Measure the resistance according to the value(s) in the table below.
- INSPECT NO. 2 IGNITION RELAY (IG2 NO. 1)
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 3 - 5 Battery voltage not applied between terminals 1 and 2 10 kΩ or higher Battery voltage applied between terminals 1 and 2 Below 1 Ω If the result is not as specified, replace the No. 2 ignition relay (IG2 NO. 1).
- Measure the resistance according to the value(s) in the table below.