DTC P0597-12: Thermostat Heater Control Circuit Short to Battery [12/2019 - 10/2021]: Procedure
WARNING: This page is about a different variant/trim than selected.
- CHECK HARNESS AND CONNECTOR (THERMOSTAT HEATER (WATER INLET WITH THERMOSTAT SUB-ASSEMBLY) - ECM)
- Disconnect the thermostat heater (water inlet with thermostat sub-assembly) connector.
- Disconnect the ECM connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition n6-2 (ETM-) or C55-7 (HTHM) - Other terminals Always 10 kΩ or higher Result
Proceed to OK NG
Result:
OK
REPLACE ECM
Refer to REMOVAL [12/2019 - 10/2022]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR