Typical Enabling Conditions
WARNING: This page is about a different variant/trim than selected.
P05A2: ACTIVE GRILLE AIR SHUTTER MOTOR DRIVE MOSFET OPEN MONITOR (CASE 1)
| Monitor runs whenever the following DTCs are not stored | None |
| All of the following conditions are met | - |
| Either of the following conditions is met | 1 or 2 |
| 1. Both of the following conditions are met | (a) and (b) |
| (a). Command to close active grille air shutter | On |
| (b). Active grille air shutter close control | Not operating |
| 2. Both of the following conditions are met | (c) and (d) |
| (c). Command to open active grille air shutter | On |
| (d). Active grille air shutter open control | Not operating |
| Active grille air shutter control re-try operation | Off |
| Reverse motor control during shutter position check | Not operating |
| Auxiliary battery voltage | 10.5 to 16 V |
| Active grille air shutter motor drive MOSFET 1 | On |
| Active grille air shutter motor drive MOSFET 2 | Off |
| Active grille air shutter motor drive MOSFET 3 | Off |
| Active grille air shutter motor drive MOSFET 4 | Off |
P05A2: ACTIVE GRILLE AIR SHUTTER MOTOR DRIVE MOSFET OPEN MONITOR (CASE 2)
| Monitor runs whenever the following DTCs are not stored | None |
| All of the following conditions are met | - |
| Either of the following conditions is met | 1 or 2 |
| 1. Both of the following conditions are met | (a) and (b) |
| (a). Command to close active grille air shutter | On |
| (b). Active grille air shutter close control | Not operating |
| 2. Both of the following conditions are met | (c) and (d) |
| (c). Command to open active grille air shutter | On |
| (d). Active grille air shutter open control | Not operating |
| Active grille air shutter control re-try operation | Off |
| Reverse motor control during shutter position check | Not operating |
| Auxiliary battery voltage | 10.5 to 16 V |
| Active grille air shutter motor drive MOSFET 1 | Off |
| Active grille air shutter motor drive MOSFET 2 | On |
| Active grille air shutter motor drive MOSFET 3 | Off |
| Active grille air shutter motor drive MOSFET 4 | Off |
P05A2: ACTIVE GRILLE AIR SHUTTER MOTOR DRIVE MOSFET OPEN MONITOR (CASE 3)
| Monitor runs whenever the following DTCs are not stored | None |
| All of the following conditions are met | - |
| Either of the following conditions is met | 1 or 2 |
| 1. Both of the following conditions are met | (a) and (b) |
| (a). Command to close active grille air shutter | On |
| (b). Active grille air shutter close control | Not operating |
| 2. Both of the following conditions are met | (c) and (d) |
| (c). Command to open active grille air shutter | On |
| (d). Active grille air shutter open control | Not operating |
| Active grille air shutter control re-try operation | Off |
| Reverse motor control during shutter position check | Not operating |
| Auxiliary battery voltage | 10.5 to 16 V |
| Active grille air shutter motor drive MOSFET 1 | Off |
| Active grille air shutter motor drive MOSFET 2 | Off |
| Active grille air shutter motor drive MOSFET 3 | On |
| Active grille air shutter motor drive MOSFET 4 | Off |
P05A2: ACTIVE GRILLE AIR SHUTTER MOTOR DRIVE MOSFET OPEN MONITOR (CASE 4)
| Monitor runs whenever the following DTCs are not stored | None |
| All of the following conditions are met | - |
| Either of the following conditions is met | 1 or 2 |
| 1. Both of the following conditions are met | (a) and (b) |
| (a). Command to close active grille air shutter | On |
| (b). Active grille air shutter close control | Not operating |
| 2. Both of the following conditions are met | (c) and (d) |
| (c). Command to open active grille air shutter | On |
| (d). Active grille air shutter open control | Not operating |
| Active grille air shutter control re-try operation | Off |
| Reverse motor control during shutter position check | Not operating |
| Auxiliary battery voltage | 10.5 to 16 V |
| Active grille air shutter motor drive MOSFET 1 | Off |
| Active grille air shutter motor drive MOSFET 2 | Off |
| Active grille air shutter motor drive MOSFET 3 | Off |
| Active grille air shutter motor drive MOSFET 4 | On |
P05A2: ACTIVE GRILLE AIR SHUTTER CONTROL MODULE PERFORMANCE
| Monitor runs whenever the following DTCs are not stored | None |
P05A4, P05A5
| Monitor runs whenever the following DTCs are not stored | None |
| All of the following conditions are met | - |
| Either of the following conditions is met | 1 or 2 |
| 1. Both of the following conditions are met | (a) and (b) |
| (a). Command to close active grille air shutter | On |
| (b). Active grille air shutter close control | Not operating |
| 2. Both of the following conditions are met | (c) and (d) |
| (c). Command to open active grille air shutter | On |
| (d). Active grille air shutter open control | Not operating |
| Active grille air shutter control re-try operation | Off |
| Reverse motor control during shutter position check | Not operating |
| Auxiliary battery voltage | 10.5 to 16 V |
| Active grille air shutter motor drive MOSFET 1 | Off |
| Active grille air shutter motor drive MOSFET 2 | Off |
| Active grille air shutter motor drive MOSFET 3 | Off |
| Active grille air shutter motor drive MOSFET 4 | Off |