Inspection [12/2019 - ]: Procedure
WARNING: This page is about a different variant/trim than selected.
- INSPECT FUEL VAPOR CONTAINMENT VALVE (CLOSE TANK WITH BOLT VALVE ASSEMBLY)
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 1 (+UL) - 2 (+UM) 20°C (68°F) 29 to 33 Ω 3 (+UN) - 4 (+UP) If the result is not as specified, replace the fuel vapor containment valve (close tank with bolt valve assembly).
*a Component without wire harness connected
(Fuel Vapor Containment Valve (Close Tank with Bolt Valve Assembly))
- Measure the resistance according to the value(s) in the table below.