DTC B1476: A/C Inverter Load System [12/2019 - 11/2023]: Procedure
- CHECK CAN COMMUNICATION SYSTEM
- Using the GTS, check if the CAN communication system is functioning normally.
Refer to HOW TO PROCEED WITH TROUBLESHOOTING [12/2019 - 10/2021] , or refer to HOW TO PROCEED WITH TROUBLESHOOTING [10/2021 - 10/2022] , or refer to HOW TO PROCEED WITH TROUBLESHOOTING [10/2022 - 11/2023]
Result
Result Proceed to CAN communication system DTCs are not output A CAN communication system DTCs are output B
Result:
B
GO TO CAN COMMUNICATION SYSTEM. Refer to HOW TO PROCEED WITH TROUBLESHOOTING [12/2019 - 10/2021] , or refer to HOW TO PROCEED WITH TROUBLESHOOTING [10/2021 - 10/2022] , or refer to HOW TO PROCEED WITH TROUBLESHOOTING [10/2022 - 11/2023]
Result:
A
See step 2
- Using the GTS, check if the CAN communication system is functioning normally.
- PERFORM ACTIVE TEST USING GTS (CONTROL THE ENGINE COOLING FAN DUTY RATIO)
- Perform the Active Test according to the display on the GTS.
Powertrain > Engine > Active Test
Tester Display Measurement Item Control Range Restrict Condition Control the Engine Cooling Fan Duty Ratio Control the cooling fan 0 to 100% Perform this test when vehicle is stopped. Powertrain > Engine > Active Test
Tester Display Control the Engine Cooling Fan Duty Ratio OK
Electric cooling fan operates smoothly.
Result
Proceed to OK NG
Result:
NG
GO TO COOLING FAN SYSTEM. Refer to ON-VEHICLE INSPECTION [12/2019 - ]
Result:
OK
See step 3
- Perform the Active Test according to the display on the GTS.
- CHECK REFRIGERANT PRESSURE
- Install a manifold gauge set.
Refer to ON-VEHICLE INSPECTION [12/2019 - ]
- Prepare the vehicle according to the table below.MEASUREMENT CONDITION:
Item Condition Vehicle Condition Ignition switch ON (READY) Doors Fully closed (windows also fully closed) A/C Switch On Recirculation/fresh Control Switch Recirculation Set Temperature MAX COLD Blower Speed HI Air Conditioning Air Inlet Temperature 25 to 35°C (77 to 95°F) - Read the manifold gauge pressure.
Standard Pressure
Low pressure side
150 to 250 kPa (1.5 to 2.5 kgf/cm2 , 22 to 36 psi)
High pressure side
1370 to 1570 kPa (14 to 16 kgf/cm2 , 199 to 228 psi)
Result
Proceed to OK NG
Result:
OK
REPLACE COMPRESSOR WITH MOTOR ASSEMBLY. Refer to REMOVAL [12/2019 - 10/2022] , or refer to REMOVAL [10/2022 - 11/2023]
Result:
NG
CHARGE REFRIGERANT. Refer to REPLACEMENT [12/2019 - ]
- Install a manifold gauge set.