DTC P0534-7A: Refrigerant Gas Fluid Leak or Seal Failure [11/2023 - ]: Procedure
- CHECK REFRIGERANT PRESSURE
Pre-procedure1
- Install a manifold gauge set.
HINT:
Refer to ON-VEHICLE INSPECTION [12/2019 - ]
- Prepare the vehicle according to the table below.
Measurement Condition
Item Condition Doors Fully open A/C Switch On Recirculation/fresh Control Switch Recirculation Set Temperature MAX COLD Blower Speed HI Air Conditioning Air Inlet Temperature 25 to 35°C (77 to 95°F) Procedure1
- Compare the values displayed in the Data List and on the manifold gauge.
Body Electrical > Air Conditioner > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note Regulator Pressure Sensor Air conditioning pressure sensor -32768 to 32767 kPa (gauge) (-32.768 to 32.767 MPaG) Actual refrigerant pressure displayed - Refrigerant line (gas leak etc.)
- Air conditioning pressure sensor circuit malfunction
Body Electrical > Air Conditioner > Data List
Tester Display Regulator Pressure Sensor Result
Result Proceed to Data List value and manifold gauge set value do not match A Data List value matches manifold gauge set value B Post-procedure1
- None
Result:
B
INSPECT REFRIGERANT PRESSURE WITH MANIFOLD GAUGE SET. Refer to ON-VEHICLE INSPECTION [12/2019 - ]
Result:
A
See step 2
- Install a manifold gauge set.
- CHECK HARNESS AND CONNECTOR (AIR CONDITIONING PRESSURE SENSOR - POWER SOURCE)
Pre-procedure1
- Disconnect the A24 air conditioning pressure sensor connector.
Procedure1
- Measure the voltage according to the value(s) in the table below.
*a Front view of wire harness connector
(to Air Conditioning Pressure Sensor)Standard Voltage
Tester Connection Condition Specified Condition A24-3 (+) - Body ground Ignition switch ON 4.75 to 5.25 V Result
Proceed to OK NG Post-procedure1
- None
Result:
NG
See step 7
Result:
OK
See step 3
- Disconnect the A24 air conditioning pressure sensor connector.
- CHECK HARNESS AND CONNECTOR (AIR CONDITIONING PRESSURE SENSOR - BODY GROUND)
Pre-procedure1
- Disconnect the A24 air conditioning pressure sensor connector.
Procedure1
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition A24-1 (-) - Body ground Always Below 1 Ω *a Front view of wire harness connector
(to Air Conditioning Pressure Sensor)Result
Proceed to OK NG Post-procedure1
- None
Result:
NG
See step 6
Result:
OK
See step 4
- Disconnect the A24 air conditioning pressure sensor connector.
- CHECK HARNESS AND CONNECTOR (AIR CONDITIONING PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER ASSEMBLY)
Pre-procedure1
- Disconnect the A24 air conditioning pressure sensor connector.
- Disconnect the H63 air conditioning amplifier assembly connector.
Procedure1
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition A24-2 (PR) - H63-6 (PRE) Always Below 1 Ω A24-2 (PR) or H63-6 (PRE) - Other terminals and body ground Always 10 kΩ or higher Result
Proceed to OK NG Post-procedure1
- None
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 5
- INSPECT AIR CONDITIONING AMPLIFIER ASSEMBLY (SENSOR SIGNAL CIRCUIT) NOTE:
- If refrigerant pressure on the high pressure side becomes extremely high, the fail-safe function stops compressor operation.
- It is necessary to measure the voltage for a certain amount of time (approximately 10 minutes) because the malfunction may recur after a while.
HINT:
When the outside air temperature is low (below -1.5°C (29.3°F)), the compressor stops due to operation of the ambient temp. sensor (cooler thermistor) and the evaporator temp. sensor (No. 1 cooler thermistor) to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.
Pre-procedure1
- Connect the H63 air conditioning amplifier assembly connector.
- Connect the A24 air conditioning pressure sensor connector.
- Prepare the vehicle according to the table below.
Measurement Condition
Item Condition Doors Fully open A/C Switch On Recirculation/fresh Control Switch Recirculation Set Temperature MAX COLD Blower Speed HI Air Conditioning Air Inlet Temperature 25 to 35°C (77 to 95°F) Procedure1
- Measure the voltage according to the value(s) in the table below.
*a Component with harness connected
(Air Conditioning Amplifier Assembly)- - Standard Voltage
Tester Connection Condition Specified Condition H63-6 (PRE) - Body ground A/C Switch ON (When compressor with motor assembly running) 0.74 to 4.61 V - Read the Data List according to the display on the GTS.
Body Electrical > Air Conditioner > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note Regulator Pressure Sensor Air conditioning pressure sensor -32768 to 32767 kPa (gauge) (-32.768 to 32.767 MPaG) Actual refrigerant pressure displayed - Refrigerant line (gas leak etc.)
- Air conditioning pressure sensor circuit malfunction
Body Electrical > Air Conditioner > Data List
Tester Display Regulator Pressure Sensor OK
The voltage and value displayed in the Data List change.
Result
Result Proceed to OK A NG (The voltage changes but the value displayed in the Data List does not change.) B NG (The voltage does not change.) C Post-procedure1
- None
Result:
A
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY. Refer to REMOVAL [11/2023 - ]
Result:
B
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY. Refer to REMOVAL [11/2023 - ]
Result:
C
REPLACE AIR CONDITIONING PRESSURE SENSOR. Refer to REMOVAL [10/2022 - ]
- CHECK HARNESS AND CONNECTOR (AIR CONDITIONING PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER ASSEMBLY)
Pre-procedure1
- Disconnect the A24 air conditioning pressure sensor connector.
- Disconnect the H63 air conditioning amplifier assembly connector.
Procedure1
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition A24-1 (-) - H63-15 (SG-4) Always Below 1 Ω A24-1 (-) or H63-15 (SG-4) - Other terminals and body ground Always 10 kΩ or higher Result
Proceed to OK NG Post-procedure1
- None
Result:
OK
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY. Refer to REMOVAL [11/2023 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
- CHECK HARNESS AND CONNECTOR (AIR CONDITIONING PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER ASSEMBLY)
Pre-procedure1
- Disconnect the A24 air conditioning pressure sensor connector.
- Disconnect the H63 air conditioning amplifier assembly connector.
Procedure1
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition A24-3 (+) - H63-11 (S5-3) Always Below 1 Ω A24-3 (+) or H63-11 (S5-3) - Other terminals and body ground Always 10 kΩ or higher Result
Proceed to OK NG Post-procedure1
- None
Result:
OK
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY. Refer to REMOVAL [11/2023 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR