DTC P058A-01: Auxiliary Battery Monitor Module Range/Performance [11/2023 - ]: Procedure
- CHECK DTC OUTPUT (HYBRID CONTROL)
- Check for DTCs.
Powertrain > Hybrid Control > Trouble Codes
Result
Result Proceed to P162B-87 is not output A P162B-87 is output B HINT:
When P162B-87 (Lost Communication with Battery Monitor Module Missing Message) is output at the same time, perform troubleshooting for P162B-87 (Lost Communication with Battery Monitor Module Missing Message) first.
Result:
B
GO TO DTC CHART (P162B-87). Refer to DTC P162B-87: Lost Communication with Battery Monitor Module Missing Message [11/2023 - ]
Result:
A
See step 2
- Check for DTCs.
- CHECK BATTERY STATE SENSOR ASSEMBLY INSTALLATION CONDITION
HINT:
Refer to INSTALLATION [11/2023 - ]
Result
Proceed to OK NG Result:
NG
INSTALL BATTERY STATE SENSOR ASSEMBLY CORRECTLY. Refer to INSTALLATION [11/2023 - ]
Result:
OK
See step 3
- CHECK HARNESS AND CONNECTOR (POWER SOURCE CIRCUIT)
Pre-procedure1
- Turn the ignition switch off.
- Check that the battery state sensor assembly connector is securely connected.
OK
The connector is securely connected.
- Disconnect the M107 battery state sensor assembly connector.
- Check the connector case and terminals for deformation or corrosion.
OK
No deformation or corrosion.
Procedure1
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition M107-3 (+B) - Body ground Ignition switch off 11 to 14 V M107-1 (RBAT) - Body ground Ignition switch off 11 to 14 V Result
Proceed to OK NG Post-procedure1
- None
Result:
OK
REPLACE BATTERY STATE SENSOR ASSEMBLY. Refer to REMOVAL [11/2023 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (BATTERY STATE SENSOR ASSEMBLY - AUXILIARY BATTERY)