DSD Information System
Home >> Toyota >> 2021 >> Highlander LE, 4WD >> Repair and Diagnosis >> Electrical >> Charging Systems >> Battery / Charging System (W/O Stop And Start System) (2GR-FKS) - Diagnostics - Introduction >> CHARGING SYSTEM (w/o Stop And Start System) >> Precaution [12/2019 - 10/2022] >> Precaution [12/2019 - 10/2022]

Precaution [12/2019 - 10/2022]

  1. INITIALIZATION 
    NOTE:

    Make sure to perform the necessary procedures (adjustment, calibration, initialization, or registration) after parts related to the cable has been disconnected from the negative (-) battery terminal.

    Refer to INITIALIZATION [12/2019 - 09/2020] , or refer to INITIALIZATION [09/2020 - 10/2021] , or refer to INITIALIZATION [10/2021 - 10/2022]

  2. CHARGING SYSTEM PRECAUTION 
    NOTE:
    • Check that the battery cables are connected to the correct terminals.
    • Disconnect the battery cables when the battery is given a quick charge.
    • Do not perform tests with a high voltage insulation resistance tester.
    • Never disconnect the battery cables while the engine is running.
    • Check that the charging cable nuts are tightened on terminal B of the generator assembly and on the No. 1 engine room relay block and No. 1 junction block assembly.