Blind Spot Monitor Sensor Communication Stop Mode [10/2022 - 11/2023]: Procedure
- CHECK FOR OPEN IN CAN BUS LINES (BLIND SPOT MONITOR SENSOR LH BRANCH LINE)
- Disconnect the cable from the negative (-) battery terminal.
- Disconnect the M43 blind spot monitor sensor LH connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition M43-2 (CA1P) - M43-7 (CA1N) Cable disconnected from negative (-) battery terminal 54 to 69 Ω *a Front view of wire harness connector
(to Blind Spot Monitor Sensor LH)Result
Result OK NG
Result:
NG
REPAIR OR REPLACE CAN BRANCH LINES OR CONNECTOR (BLIND SPOT MONITOR SENSOR LH)
Result:
OK
See step 2
- CHECK HARNESS AND CONNECTOR (GROUND CIRCUIT)
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition M43-10 (BLGD) - Body ground Cable disconnected from negative (-) battery terminal Below 1 Ω *a Front view of wire harness connector
(to Blind Spot Monitor Sensor LH)Result
Result OK NG
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (GROUND CIRCUIT)
Result:
OK
See step 3
- Measure the resistance according to the value(s) in the table below.
- CHECK VEHICLE TYPE
Result:
B
See step 5
Result:
A
See step 4
- CHECK HARNESS AND CONNECTOR (POWER SOURCE CIRCUIT)
- Reconnect the cable to the negative (-) battery terminal.
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition M43-5 (BLB) - Body ground Ignition switch ON 10.5 to 16 V *a Front view of wire harness connector
(to Blind Spot Monitor Sensor LH)Result
Result OK NG
Result:
OK
REPLACE BLIND SPOT MONITOR SENSOR LH
Refer to REMOVAL [10/2022 - 11/2023]
Result:
NG
GO TO STOP AND START SYSTEM (FOR BACKUP BOOST CONVERTER CIRCUIT)
- CHECK HARNESS AND CONNECTOR (POWER SOURCE CIRCUIT)
- Reconnect the cable to the negative (-) battery terminal.
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition M43-5 (BLB) - Body ground Ignition switch ON 11 to 14 V *a Front view of wire harness connector
(to Blind Spot Monitor Sensor LH)Result
Result OK NG
Result:
OK
REPLACE BLIND SPOT MONITOR SENSOR LH
Refer to REMOVAL [10/2022 - 11/2023]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (POWER SOURCE CIRCUIT)