Blind Spot Monitor Sensor Communication Stop Mode [11/2023 - ]: Procedure
- CHECK FOR OPEN IN CAN BUS LINES (BLIND SPOT MONITOR SENSOR LH (B) BRANCH LINE)
- Disconnect the cable from the negative (-) battery terminal.
- Disconnect the M43 blind spot monitor sensor LH (B) connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition M43-2 (CA1P) - M43-7 (CA1N) Cable disconnected from negative (-) battery terminal 54 to 69 Ω *a Front view of wire harness connector
(to Blind Spot Monitor Sensor LH (B))Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE CAN BRANCH LINES OR CONNECTOR (BLIND SPOT MONITOR SENSOR LH (B))
Result:
OK
See step 2
- CHECK HARNESS AND CONNECTOR (POWER SOURCE CIRCUIT)
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition M43-10 (BLGD) - Body ground Cable disconnected from negative (-) battery terminal Below 1 Ω *a Front view of wire harness connector
(to Blind Spot Monitor Sensor LH (B)) - Reconnect the cable to the negative (-) battery terminal.
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition M43-5 (BLB) - Body ground Ignition switch ON 11 to 14 V Result
Proceed to OK NG
Result:
OK
REPLACE BLIND SPOT MONITOR SENSOR LH (B)
Refer to REMOVAL [11/2023 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (POWER SOURCE CIRCUIT)
- Measure the resistance according to the value(s) in the table below.