DTC P26CA-12: Engine Coolant Pump Circuit Short to Battery [10/2022 - 11/2023]: Procedure
- CHECK TERMINAL VOLTAGE (POWER SOURCE OF WATER INLET HOUSING WITH WATER PUMP SUB-ASSEMBLY)
*a Front view of wire harness connector
(to Water Inlet Housing with Water Pump Sub-assembly)- Disconnect the water inlet housing with water pump sub-assembly connector.
- Turn the ignition switch to ON.
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition C39-2 (SWP) - Body ground Ignition switch ON Below 1 V Result
Proceed to OK NG
Result:
NG
See step 3
Result:
OK
See step 2
- INSPECT ECM (INTERNAL CIRCUIT)
*a Front view of wire harness connector
(to Water Inlet Housing with Water Pump Sub-assembly)- Disconnect the water inlet housing with water pump sub-assembly connector.
- Turn the ignition switch to ON.
- Perform the Active Test using the GTS.
Powertrain > Engine > Active Test
Tester Display Activate the Electric Water Pump - Measure the resistance according to the value(s) in the table below.
Standard
Tester Connection Condition Specified Condition C39-2 (SWP) - Body ground During Active Test Resistance fluctuates* HINT:
*: Using the Active Test, duty control of the transistors in the ECM will be performed. Due to the duty control, resistance of the SWP terminal will be unstable during the Active Test. If the resistance fluctuates while performing the Active Test, it can be determined that the transistor is operating. If the transistor does not operate during the Active Test, the ECM may be malfunctioning.
Result
Proceed to OK NG
Result:
OK
REPLACE WATER INLET HOUSING WITH WATER PUMP SUB-ASSEMBLY
Refer to REMOVAL [12/2019 - ]
Result:
NG
REPLACE ECM
Refer to REMOVAL [10/2022 - 11/2023]
- CHECK HARNESS AND CONNECTOR (WATER INLET HOUSING WITH WATER PUMP SUB-ASSEMBLY - ECM)
- Disconnect the water inlet housing with water pump sub-assembly connector.
- Disconnect the ECM connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition C39-2 (SWP) or C55-50 (WPO) - Other terminals Always 10 kΩ or higher Result
Proceed to OK NG
Result:
OK
REPLACE ECM
Refer to REMOVAL [10/2022 - 11/2023]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR