Typical Malfunction Thresholds
WARNING: This page is about a different variant/trim than selected.
| One of the following conditions is met | A, B or C |
| A. Both of the following conditions are met | 10 times or more |
| Command to injector | Off |
| Injector voltage detected by injector driver IC | [Auxiliary battery voltage multiplied by 0.55] V or less |
| B. Both of the following conditions are met | 10 times or more |
| Command to injector | Off |
| Injector voltage detected by injector driver IC | Higher than [auxiliary battery voltage multiplied by 0.55] V, and [auxiliary battery voltage multiplied by 0.7] V or less |
| C. One of the following conditions is met | (a), (b) or (c) |
| (a) Both of the following conditions are met | 10 times or more |
| Command to injector | On |
| Injector voltage detected by injector driver IC | [Auxiliary battery voltage multiplied by 0.12] V or higher |
| (b) Both of the following conditions are met | 10 times or more |
| Command to injector | On |
| Injector current detected by injector driver IC | 2.6 A or higher |
| (c) Following condition is met | 10 times or more |
| Injector driver IC internal temperature detected by injector driver IC | 150°C (302°F) or higher |