- P1422-00: Small leak from fuel tank
In operation G, the leak detection pump creates negative pressure (vacuum) in the fuel tank and the fuel tank pressure is measured. If the stabilized system pressure is higher than the third reference pressure, the ECM determines that the fuel tank has a small leak. The ECM illuminates the MIL and stores the DTC (2 trip detection logic).
- P1423-00: Gross leak from fuel tank
In operation G, the leak detection pump creates negative pressure (vacuum) in the fuel tank and the fuel tank pressure is measured. If the stabilized system pressure is higher than [third reference pressure x 0.2] (near atmospheric pressure), the ECM determines that the fuel tank has a large leak. The ECM illuminates the MIL and stores the DTC (2 trip detection logic).