DTC P106A-62: Evaporative Emission System Pressure / Intake Air Pressure Signal Compare Failure; DTC P106C-62: Evaporative Emission System Pressure/Barometric Pressure Signal Compare Failure [11/2023 - ]: Procedure
WARNING: This page is about a different variant/trim than selected.
- CHECK ANY OTHER DTCS OUTPUT (IN ADDITION TO DTC P106A-62 AND/OR P106C-62)
- Read the DTCs.
Powertrain > Engine > Trouble Codes
Result
Result Proceed to DTC P106A-62 is output A DTC P106C-62 is output B DTC P106A-62 and P106C-62 are output C DTC P106A-62 and/or P106C-62 and other DTCs are output D HINT:
If any DTCs other than P106A-62 and/or P106C-62 are output, troubleshoot those DTCs first.
Result:
B
See step 3
Result:
C
See step 4
Result:
D
GO TO DTC CHART . Refer to DIAGNOSTIC TROUBLE CODE CHART [11/2023 - 11/2024] , or refer to DIAGNOSTIC TROUBLE CODE CHART [11/2024 - ]
Result:
A
See step 2
- Read the DTCs.
- REPLACE MANIFOLD ABSOLUTE PRESSURE SENSOR
Refer to REMOVAL [12/2019 - ]
Result
Proceed to NEXT Result:
NEXT
See step 5
- REPLACE ECM (ATMOSPHERIC PRESSURE SENSOR)
Refer to REMOVAL [11/2023 - ]
Result
Proceed to NEXT Result:
NEXT
See step 5
- REPLACE CANISTER PUMP MODULE
Refer to REMOVAL [12/2019 - ]
Result
Proceed to NEXT Result:
NEXT
See step 5
- CLEAR DTC
- Clear the DTCs.
Powertrain > Engine > Clear DTCs
- Turn the ignition switch off and wait for at least 30 seconds.
Result
Proceed to NEXT
Result:
NEXT
See step 6
- Clear the DTCs.
- CONFIRM WHETHER MALFUNCTION HAS BEEN SUCCESSFULLY REPAIRED
- Confirm that the difference between Intake Manifold Absolute Pressure and Vapor Pressure Pump is 8.69 kPa (1.26 psi) or less.
Powertrain > Engine > Data List
Tester Display Intake Manifold Absolute Pressure Vapor Pressure Pump - Confirm that the difference between Atmospheric Pressure and Vapor Pressure Pump is 7.89 kPa (1.14 psi) or less.
Powertrain > Engine > Data List
Tester Display Atmospheric Pressure Vapor Pressure Pump Result
Proceed to NEXT
Result:
NEXT
END
- Confirm that the difference between Intake Manifold Absolute Pressure and Vapor Pressure Pump is 8.69 kPa (1.26 psi) or less.