DTC P107A-11: Fuel Rail Pressure Sensor (Low) Circuit Short to Ground [11/2023 - ]: Procedure
WARNING: This page is about a different variant/trim than selected.
- CHECK HARNESS AND CONNECTOR
*a Front view of wire harness connector
(to No. 2 Fuel Pressure Sensor (for Low Pressure Side))HINT:
Make sure that the connector is properly connected. If it is not, securely connect it and check for DTCs again.
- Disconnect the No. 2 fuel pressure sensor (for low pressure side) connector.
- Turn the ignition switch to ON.
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition D11-1 (VC) - D11-3 (E2) Ignition switch ON 4.75 to 5.25 V D11-2 (PFL) - D11-3 (E2) Ignition switch ON 0.57 to 4.88 V - Turn the ignition switch off and wait for at least 30 seconds.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition D11-1 (VC) - D11-2 (PFL) Ignition switch off 171 to 189 kΩ HINT:
Perform "Inspection After Repair" after replacing the No. 2 fuel pressure sensor (for low pressure side).
Refer to INITIALIZATION [10/2021 - ]
Result
Proceed to OK NG
Result:
OK
REPLACE NO. 2 FUEL PRESSURE SENSOR (FOR LOW PRESSURE SIDE)
Refer to REMOVAL [11/2023 - ]
Result:
NG
See step 2
- CHECK HARNESS AND CONNECTOR (NO. 2 FUEL PRESSURE SENSOR (FOR LOW PRESSURE SIDE) - ECM)
- Disconnect the No. 2 fuel pressure sensor (for low pressure side) connector.
- Disconnect the ECM connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition D11-1 (VC) - C55-84 (VCPF) Always Below 1 Ω D11-2 (PFL) or C55-107 (PFL) - Body ground and other terminals Always 10 kΩ or higher Result
Proceed to OK NG
Result:
OK
REPLACE ECM
Refer to REMOVAL [11/2023 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR