Typical Malfunction Thresholds
WARNING: This page is about a different variant/trim than selected.
P05B2
| Number of active grille air shutter motor speed sensor 1 signal pulse | Less than 1 time |
P05B3
| Either of the following conditions is met | 1 or 2 |
| 1. Both of the following conditions are met | - |
| Number of active grille air shutter motor speed sensor 1 signal pulse | Several |
| Active grille air shutter motor speed sensor 2 terminal voltage level | High |
| 2. Both of the following conditions are met | - |
| Number of active grille air shutter motor speed sensor 2 signal pulse | Several |
| Active grille air shutter motor speed sensor 1 terminal voltage level | High |
P05B4
| Either of the following conditions is met | 1 or 2 |
| 1. Both of the following conditions are met | - |
| Number of active grille air shutter motor speed sensor 1 signal pulse | Several |
| Active grille air shutter motor speed sensor 2 terminal voltage level | Low |
| 2. Both of the following conditions are met | - |
| Number of active grille air shutter motor speed sensor 2 signal pulse | Several |
| Active grille air shutter motor speed sensor 1 terminal voltage level | Low |