| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Memory | Note |
|---|---|---|---|---|---|---|
| P043E-00 | Evaporative Emission System Leak Detection Reference Orifice Low Flow | Reference orifice detected as clogged during key-off EVAP monitor. |
|
Comes on | DTC stored |
|
| P043F-00 | Evaporative Emission System Leak Detection Reference Orifice High Flow | Reference orifice flow high during key-off EVAP monitor. |
|
Comes on | DTC stored |
|
| P0446-72 | EVAP System Vent Valve Stuck Open Actuator Stuck Open | Vent valve on (closed) malfunction detected during key-off EVAP monitor. |
|
Comes on | DTC stored |
|
| P2400-7E | Evaporative Emission System Leak Detection Pump Control Circuit Actuator Stuck On | Leak detection pump on malfunction detected during key-off EVAP monitor. |
|
Comes on | DTC stored |
|
| P2400-7F | Evaporative Emission System Leak Detection Pump Control Circuit Actuator Stuck Off | Leak detection pump off malfunction detected during key-off EVAP monitor. |
|
Comes on | DTC stored |
|
HINT:
The reference orifice is located inside the canister pump module.
| DTC No. | Monitoring Item | Detection Timing | Detection Logic | SAE Code |
|---|---|---|---|---|
| P043E-00 | Reference orifice low flow | EVAP monitoring (ignition switch off) |
2 trip | P043E |
| P043F-00 | Reference orifice high flow | P043F | ||
| P0446-72 | Vent valve (built into canister pump module) stuck open | P2421 | ||
| P2400-7E | Leak detection pump (built into canister pump module) stuck on | P2402 | ||
| P2400-7F | Leak detection pump (built into canister pump module) stuck off | P2401 |