Typical Malfunction Thresholds
WARNING: This page is about a different variant/trim than selected.
P0201, P0202, P0203 AND P0204
| One of the following conditions is met | A, B or C |
| A. No confirmed injection signal input | 20 times or more |
| B. Both of the following conditions are met | 40 times or more |
| Current injector voltage for the same INJECTOR DRIVER FAIL SIGNAL* detected by injector driver IC | 4.8 V or higher |
| Last injector voltage for the same INJECTOR DRIVER FAIL SIGNAL* detected by injector driver IC | 4.8 V or higher |
| C. Either of the following conditions is met | (a) or (b) |
| (a) Both of the following conditions are met | 20 times or more |
| Current injector driver MOSFET current detected by injector driver IC | 30 A or more |
| Last injector driver MOSFET current detected by injector driver IC | 30 A or more |
| (b) Both of the following conditions are met | 1 and 2 |
| 1. Either of the following conditions is met | 20 times or more |
| Current injector current during peak current control for the same INJECTOR DRIVER FAIL SIGNAL* detected by injector driver IC | 125 A or more |
| Current injector current during hold current control for the same INJECTOR DRIVER FAIL SIGNAL* detected by injector driver IC | 100 A or more |
| 2. Either of the following conditions is met | 20 times or more |
| Last injector current during peak current control for the same INJECTOR DRIVER FAIL SIGNAL* detected by injector driver IC | 125 A or more |
| Last injector current during hold current control for the same INJECTOR DRIVER FAIL SIGNAL* detected by injector driver IC | 100 A or more |
P062D
| No confirmed injection signal input in all cylinders | 60 times or more |
| *: Definition of the INJECTOR DRIVER FAIL SIGNAL | - |
| INJECTOR DRIVER FAIL SIGNAL 1 | #1 and #4 |
| INJECTOR DRIVER FAIL SIGNAL 2 | #2 and #3 |