DSD Information System
Home >> Toyota >> 2021 >> Highlander LE, 4WD >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 94 (Motor Generator Control System (2WD) - Diagnostic Codes (3 Of 4)) >> MOTOR GENERATOR CONTROL SYSTEM (for 2WD) >> DTC P0E51-28: DC/DC Converter Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure [12/2019 - 11/2023] >> Confirmation Driving Pattern

Confirmation Driving Pattern

WARNING: This page is about a different variant/trim than selected.

HINT: 

  1. Connect the GTS to the DLC3.
  2. Turn the ignition switch to ON and turn the GTS on.
  3. Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
  4. Turn the ignition switch off and wait for 2 minutes or more.
  5. Turn the ignition switch to ON and turn the GTS on.
  6. With the ignition switch ON and wait for 5 seconds or more. [*1]
  7. Turn the ignition switch to ON (READY) with the shift lever in P and wait for 5 seconds or more. [*2]

    HINT: 

    [*1] to [*2]: Normal judgment procedure.

    The normal judgment procedure is used to complete DTC judgment and also used when clearing permanent DTCs.

  8. Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.
  9. Check the DTC judgment result.

    HINT: 

    • If the judgment result shows NORMAL, the system is normal.
    • If the judgment result shows ABNORMAL, the system has a malfunction.
    • If the judgment result shows INCOMPLETE, perform the normal judgment procedure again.