DTC P1C2E-46: Motor Generator ECU (EEPROM) Calibration / Parameter Memory Failure [12/2019 - 11/2023]: Procedure
WARNING: This page is about a different variant/trim than selected.
- CHECK AUXILIARY BATTERY VOLTAGE
Refer to ON-VEHICLE INSPECTION [12/2019 - 11/2023]
HINT:
If the auxiliary battery voltage inspection results are normal, perform the next step.
Result
Proceed to NEXT Result:
NEXT
See step 2
- CLEAR DTC
- Clear the DTCs.
Powertrain > Motor Generator > Clear DTCs
- Turn the ignition switch off and wait for 2 minutes or more.
Result
Proceed to NEXT
Result:
NEXT
See step 3
- Clear the DTCs.
- SIMULATION TEST
- Turn the ignition switch to ON and wait for 5 seconds or more.
- Turn the ignition switch off and wait for 2 minutes or more.
- Turn the ignition switch to ON and wait for 5 seconds or more.
- Check for DTCs.
Powertrain > Motor Generator > Trouble Codes
Result
Result Proceed to P1C2E-46 is output. A P1C2E-46 is not output. B - Turn the ignition switch off.
Result:
A
REPLACE INVERTER WITH CONVERTER ASSEMBLY. Refer to REMOVAL [12/2019 - 10/2022] , or refer to REMOVAL [10/2022 - 11/2023]
Result:
B
CHECK FOR INTERMITTENT PROBLEMS. Refer to CHECK FOR INTERMITTENT PROBLEMS [12/2019 - 11/2023]