DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P06D6-1C: Generator Control Module Offset Power Circuit Voltage Out of Range; DTC P0A1A-47: Generator Control Module Watchdog / Safety MC Failure; DTC P0A1A-49: Generator Control Module Internal Electronic Failure; DTC P1C2A-1C: Generator A/D Converter Circuit Circuit Voltage Out of Range; DTC P1C2A-49: Generator A/D Converter Circuit Internal Electronic Failure; DTC P1C2B-1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B-49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C60-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C62-1F: Generator Control Module Offset Power Circuit Intermittent; DTC P3133-83: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P3133-86: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P3133-87: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P3134-83: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P3134-86: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P3134-87: Communication Error from Drive Motor "A" to Generator Missing Message [12/2019 - 11/2023]: Description
WARNING: This page is about a different variant/trim than selected.
The motor generator control ECU (MG ECU), which is built into the inverter with converter assembly, monitors its internal operation and will store DTCs if it detects a malfunction. If any of the following DTCs are output, replace the inverter with converter assembly.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
| P06B0-1C | Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range | Motor generator control ECU internal malfunction (1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning: Comes on |
| P06D6-1C | Generator Control Module Offset Power Circuit Voltage Out of Range | Motor generator control ECU internal malfunction (1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning: Comes on |
| P0A1A-47 | Generator Control Module Watchdog / Safety MC Failure | Motor generator control ECU internal malfunction (1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning: Comes on |
| P0A1A-49 | Generator Control Module Internal Electronic Failure | Motor generator control ECU internal malfunction (1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning: Comes on |
| P1C2A-1C | Generator A/D Converter Circuit Circuit Voltage Out of Range | Motor generator control ECU internal malfunction (1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning: Comes on |
| P1C2A-49 | Generator A/D Converter Circuit Internal Electronic Failure | Motor generator control ECU internal malfunction (1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning: Comes on |
| P1C2B-1C | Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range | Motor generator control ECU internal malfunction (1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning: Comes on |
| P1C2B-49 | Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure | Motor generator control ECU internal malfunction (1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning: Comes on |
| P1C60-1F | Generator Control Module Position Sensor REF Power Source Circuit Intermittent | Motor generator control ECU internal malfunction detected when DTC P0C79-17, P0D33-19, P1C5D-19 or P1C5F-19 is stored. (1 trip detection logic) |
Inverter with converter assembly | Does not come on | Master Warning: Does not come on |
| P1C62-1F | Generator Control Module Offset Power Circuit Intermittent | Motor generator control ECU internal malfunction detected when DTC P0C79-17, P0D33-19, P1C5D-19 or P1C5F-19 is stored. (1 trip detection logic) |
Inverter with converter assembly | Does not come on | Master Warning: Does not come on |
| P3133-83 | Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect | Motor generator control ECU internal malfunction (1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning: Comes on |
| P3133-86 | Communication Error from Generator to Drive Motor "A" Signal Invalid | Motor generator control ECU internal malfunction (1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning: Comes on |
| P3133-87 | Communication Error from Generator to Drive Motor "A" Missing Message | Motor generator control ECU internal malfunction (1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning: Comes on |
| P3134-83 | Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect | Motor generator control ECU internal malfunction (1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning: Comes on |
| P3134-86 | Communication Error from Drive Motor "A" to Generator Signal Invalid | Motor generator control ECU internal malfunction (1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning: Comes on |
| P3134-87 | Communication Error from Drive Motor "A" to Generator Missing Message | Motor generator control ECU internal malfunction (1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning: Comes on |