DTC P1CAC-49: Generator Position Sensor Internal Electronic Failure; DTC P1C64-1F: Generator Control Module Circuit Intermittent; DTC P1CAF-38: Generator Position Sensor REF Signal Cycle Malfunction Signal Frequency Incorrect [12/2019 - 11/2023]: Procedure
- CHECK DTC OUTPUT (MOTOR GENERATOR)
- Check for DTCs.
Powertrain > Motor Generator > Trouble Codes
Result
Result Proceed to P1CAC-49, P1CAF-38 or P1C64-1F only is output, or DTCs except the ones in the table below are also output. A Any of the following DTCs are also output. B Relevant DTC P0A3F-16 Drive Motor "A" Position Sensor Circuit Voltage Below Threshold P0A4B-16 Generator Position Sensor Circuit Voltage Below Threshold P0C64-13 Generator Position Sensor Circuit "A" Circuit Open P0C64-16 Generator Position Sensor Circuit "A" Circuit Voltage Below Threshold P0C64-17 Generator Position Sensor Circuit "A" Circuit Voltage Above Threshold P0C69-13 Generator Position Sensor Circuit "B" Circuit Open P0C69-16 Generator Position Sensor Circuit "B" Circuit Voltage Below Threshold P0C69-17 Generator Position Sensor Circuit "B" Circuit Voltage Above Threshold - Turn the ignition switch off.
Result:
B
GO TO DTC CHART (MOTOR GENERATOR CONTROL SYSTEM) . Refer to DIAGNOSTIC TROUBLE CODE CHART [12/2019 - 10/2021] , or refer to DIAGNOSTIC TROUBLE CODE CHART [10/2021 - 11/2023]
Result:
A
See step 2
- Check for DTCs.
- CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)
Refer to PROCEDURE - Step 3
Result
Result Proceed to OK A NG (The connector is not connected securely.) B NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) C Result:
B
CONNECT SECURELY
Result:
C
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
A
See step 3
- CHECK GENERATOR RESOLVER CIRCUIT
Refer to Generator Resolver Circuit [12/2019 - 11/2023]
Result
Proceed to NEXT Result:
NEXT
See step 4
- CHECK MOTOR RESOLVER CIRCUIT
Refer to Motor Resolver Circuit [12/2019 - 11/2023]
HINT:
If the "Motor Resolver Circuit" inspection results are normal, perform the next step.
Result
Proceed to NEXT Result:
NEXT
REPLACE INVERTER WITH CONVERTER ASSEMBLY
Refer to REMOVAL [12/2019 - 10/2022] , or refer to REMOVAL [10/2022 - 11/2023]