DTC P0BCC-1C: Generator Inverter Temperature Sensor Circuit Voltage Out of Range [12/2019 - 11/2023]: Description
WARNING: This page is about a different variant/trim than selected.
The motor generator control ECU (MG ECU), which is built into the inverter with converter assembly, detects the temperature of the generator inverter using the generator inverter temperature sensor. If necessary, the motor generator control ECU (MG ECU) will limit inverter output to help prevent the generator inverter from overheating. The motor generator control ECU also detects malfunctions in the sensor based on the temperature sensor values.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
| P0BCC-1C | Generator Inverter Temperature Sensor Circuit Voltage Out of Range | The actual generator inverter temperature high and the difference between the estimated generator inverter temperature and the actual temperature exceeds a threshold for 10 seconds, or after a long soak, the generator inverter temperature sensor value differs from the values of other sensors. (1 trip detection logic) |
|
Comes on | Master Warning: Comes on |
RELATED DATA LIST
| DTC No. | Data List |
|---|---|
| P0BCC-1C |
|