DSD Information System
Home >> Toyota >> 2021 >> Highlander LE, 4WD >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 90 (Heating / Air Conditioning System (HV) - Diagnostic Codes (1 Of 3)) >> AIR CONDITIONING SYSTEM (for HV Model) >> DTC B1411: Room Temperature Sensor Circuit [12/2019 - 11/2023] >> Procedure

DTC B1411: Room Temperature Sensor Circuit [12/2019 - 11/2023]: Procedure

WARNING: This page is about a different variant/trim than selected.
  1. READ VALUE USING GTS (ROOM TEMPERATURE SENSOR) 
    1. Read the Data List according to the display on the GTS.

      Body Electrical > Air Conditioner > Data List 

      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      Room Temperature Sensor Room temp. sensor (cooler thermistor) Min.: -6.50°C (20.30°F)
      Max.: 57.25°C (135.05°F)
      Actual cabin temperature displayed Room temp. sensor (cooler thermistor) circuit malfunction
      • When open circuit: -6.50°C (20.30°F)
      • When short circuit: 57.25°C (135.05°F)

      Body Electrical > Air Conditioner > Data List 

      Tester Display
      Room Temperature Sensor

      OK

      The display is as specified in the normal condition column.

      Result

      Proceed to
      OK
      NG

    Result: 

    OK 

    REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY. Refer to  REMOVAL [12/2019 - 10/2022]  , or refer to  REMOVAL [10/2022 - 11/2023] 

    Result: 

    NG 

    See step  2

  2. INSPECT ROOM TEMP. SENSOR (COOLER THERMISTOR) 

    Refer to INSPECTION [12/2019 - ]

    Result

    Proceed to
    OK
    NG

    Result: 

    NG 

    REPLACE ROOM TEMP. SENSOR (COOLER THERMISTOR). Refer to  REMOVAL [12/2019 - 10/2022]  , or refer to  REMOVAL [10/2022 - 11/2023] 

    Result: 

    OK 

    See step  3

  3. CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - ROOM TEMP. SENSOR (COOLER THERMISTOR)) 
    1. Disconnect the H63 air conditioning amplifier assembly connector.
    2. Disconnect the H55 room temp. sensor (cooler thermistor) connector.
    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection Condition Specified Condition
      H63-5 (TR) - H55-1 (+) Always Below 1 Ω
      H63-3 (SG-1) - H55-2 (-) Always Below 1 Ω
      H63-5 (TR) or H55-1 (+) - Other terminals and body ground Always 10 kΩ or higher
      H63-3 (SG-1) or H55-2 (-) - Other terminals and body ground Always 10 kΩ or higher

      Result

      Proceed to
      OK
      NG

    Result: 

    OK 

    REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY. Refer to  REMOVAL [12/2019 - 10/2022]  , or refer to  REMOVAL [10/2022 - 11/2023] 

    Result: 

    NG 

    REPAIR OR REPLACE HARNESS OR CONNECTOR