DSD Information System
Home >> Toyota >> 2021 >> Highlander LE, 4WD >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 90 (Heating / Air Conditioning System (HV) - Diagnostic Codes (1 Of 3)) >> AIR CONDITIONING SYSTEM (for HV Model) >> DTC B1419: Rear Room Temperature Sensor Circuit [12/2019 - 11/2023] >> Procedure

DTC B1419: Rear Room Temperature Sensor Circuit [12/2019 - 11/2023]: Procedure

WARNING: This page is about a different variant/trim than selected.
  1. READ VALUE USING GTS (ROOM TEMP SENSOR (REAR)) 
    1. Read the Data List according to the display on the GTS.

      Body Electrical > Air Conditioner > Data List 

      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      Room Temp Sensor (Rear) No. 2 room temp. sensor (cooler thermistor) Min.: -6.50°C (20.30°F)
      Max.: 57.25°C (135.05°F)
      Actual cabin (rear) temperature displayed No. 2 room temp. sensor (cooler thermistor) circuit malfunction
      • When open circuit: -6.50°C (20.30°F)
      • When short circuit: 57.25°C (135.05°F)

      Body Electrical > Air Conditioner > Data List 

      Tester Display
      Room Temp Sensor (Rear)

      OK

      The display is as specified in the normal condition column.

      Result

      Proceed to
      OK
      NG

    Result: 

    OK 

    REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY. Refer to  REMOVAL [12/2019 - 10/2022]  , or refer to  REMOVAL [10/2022 - 11/2023] 

    Result: 

    NG 

    See step  2

  2. INSPECT NO. 2 ROOM TEMP. SENSOR (COOLER THERMISTOR) 

    Refer to INSPECTION [12/2019 - 11/2023]

    Result

    Proceed to
    OK
    NG

    Result: 

    NG 

    REPLACE NO. 2 ROOM TEMP. SENSOR (COOLER THERMISTOR). Refer to  REMOVAL [12/2019 - 11/2023] 

    Result: 

    OK 

    See step  3

  3. CHECK HARNESS AND CONNECTOR (NO. 2 ROOM TEMP. SENSOR (COOLER THERMISTOR) - AIR CONDITIONING AMPLIFIER ASSEMBLY) 
    1. Disconnect the H65 air conditioning amplifier assembly connector.
    2. Disconnect the M16 No. 2 room temp. sensor (cooler thermistor) connector.
    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection Condition Specified Condition
      H65-8 (TR) - M16-1 (+) Always Below 1 Ω
      H65-14 (SG-8) - M16-2 (-) Always Below 1 Ω
      H65-8 (TR) - Body ground Always 10 kΩ or higher
      H65-14 (SG-8) - Body ground Always 10 kΩ or higher

      Result

      Proceed to
      OK
      NG

    Result: 

    OK 

    REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY. Refer to  REMOVAL [12/2019 - 10/2022]  , or refer to  REMOVAL [10/2022 - 11/2023] 

    Result: 

    NG 

    REPAIR OR REPLACE HARNESS OR CONNECTOR