DTC B141A-15: Room Temperature Sensor Circuit Short to Battery or Open [11/2023 - ]: Procedure
WARNING: This page is about a different variant/trim than selected.
- CHECK ROOM TEMP. SENSOR (COOLER THERMISTOR) CIRCUIT
Pre-procedure1
- Disconnect the H55 room temp. sensor (cooler thermistor) connector.
*a Front view of wire harness connector
(to Room Temp. Sensor (Cooler Thermistor))Procedure1
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition H55-1 (+) - Body ground Ignition switch ON 0 to 5.5 V Result
Proceed to OK NG Post-procedure1
- None
Result:
NG
See step 5
Result:
OK
See step 2
- Disconnect the H55 room temp. sensor (cooler thermistor) connector.
- CLEAR DTC
Result:
NEXT
See step 3
- CHECK FOR DTC
Pre-procedure1
- Turn the ignition switch off.
- Disconnect the H55 room temp. sensor (cooler thermistor) connector.
*a Front view of wire harness connector
(to Room Temp. Sensor (Cooler Thermistor)) - Connect terminals 1 and 2 of the room temp. sensor (cooler thermistor) connector on the wire harness side.
*1 Room Temp. Sensor (Cooler Thermistor) *2 Air Conditioning Amplifier Assembly - Turn the ignition switch to ON and wait for 4 seconds or more.
Procedure1
- Check for DTCs.
Body Electrical > Air Conditioner > Trouble Codes
Result
Result Proceed to B141A-11 is output A B141A-15 is output B Post-procedure1
- None
Result:
A
REPLACE ROOM TEMP. SENSOR (COOLER THERMISTOR)
Refer to REMOVAL [11/2023 - ]
Result:
B
See step 4
- CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - ROOM TEMP. SENSOR (COOLER THERMISTOR))
Pre-procedure1
- Disconnect the H55 room temp. sensor (cooler thermistor) connector.
- Disconnect the H63 air conditioning amplifier assembly connector.
Procedure1
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition H55-1 (+) - H63-5 (TR) Always Below 1 Ω H55-2 (-) - H63-3 (SG-1) Always Below 1 Ω Result
Proceed to OK NG Post-procedure1
- None
Result:
OK
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY
Refer to REMOVAL [11/2023 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
- CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - ROOM TEMP. SENSOR (COOLER THERMISTOR))
Pre-procedure1
- Disconnect the H55 room temp. sensor (cooler thermistor) connector.
- Disconnect the H63 air conditioning amplifier assembly connector.
Procedure1
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition H55-1 (+) or H63-5 (TR) - Other terminals and body ground Always 10 kΩ or higher Result
Proceed to OK NG Post-procedure1
- None
Result:
OK
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY
Refer to REMOVAL [11/2023 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR