DSD Information System
Home >> Toyota >> 2021 >> Highlander LE, 4WD >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 77 (Motor Generator Control System (AWD) - Diagnostic Codes (5 Of 5)) >> MOTOR GENERATOR CONTROL SYSTEM (for AWD) >> DTC P1CAE-49: Drive Motor "B" Position Sensor Internal Electronic Failure; DTC P1CB1-38: Drive Motor "B" Position Sensor REF Signal Frequency Incorrect [12/2019 - 11/2023] >> Monitor Description

Monitor Description

WARNING: This page is about a different variant/trim than selected.

The motor generator control ECU performs diagnostic tests to verify proper operation of internal ECU systems. In one of those tests, the motor generator control ECU checks for an R/D (Resolver/ Digital converter) malfunction involving the rear motor resolver. If the motor generator control ECU detects an R/D converter error, it will conclude that there is an internal malfunction involving the rear motor resolver. The motor generator control ECU will illuminate the MIL and set a DTC.