DTC P1C2C-1C: Drive Motor "B" Control Module AD Converter Circuit Voltage Out of Range; DTC P1C2C-49: Drive Motor "B" Control Module AD Converter Circuit Internal Electronic Failure; DTC P1C63-1F: Drive Motor "B" Control Module Offset Power Circuit Intermittent; DTC P262C-1C: Drive Motor "B" Control Module Offset Power Circuit Voltage Out of Range; DTC P310B-1F: Communication Error from Drive Motor "A" to Drive Motor "B" Circuit Intermittent; DTC P310B-83: Communication Error from Drive Motor "A" to Drive Motor "B" Value of Signal Protection Calculation Incorrect; DTC P310B-86: Communication Error from Drive Motor "A" to Drive Motor "B" Signal (Some Circuit Quantity, Reported via Serial Data) Invalid; DTC P310B-87: Communication Error from Drive Motor "A" to Drive Motor "B" Missing Message; DTC P32CF-1F: Lost Communication between Drive Motor "A" and "B" (Drive Motor "B") Circuit Intermittent; DTC P32CF-83: Lost Communication between Drive Motor "A" and "B" (Drive Motor "B") Value of Signal Protection Calculation Incorrect; DTC P32CF-86: Lost Communication between Drive Motor "A" and "B" (Drive Motor "B") Signal (Some Circuit Quantity, Reported via Serial Data) Invalid; DTC P32CF-87: Lost Communication between Drive Motor "A" and "B" (Drive Motor "B") Missing Message [12/2019 - 11/2023]: Description
WARNING: This page is about a different variant/trim than selected.
The motor generator control ECU, which is built into the inverter with converter assembly, monitors its internal operation and will store DTCs if it detects a malfunction.
If any of the following DTCs are output, replace the inverter with converter assembly.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
| P1C2C-1C | Drive Motor "B" Control Module AD Converter Circuit Voltage Out of Range | Motor generator control ECU internal malfunction (1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning: Comes on |
| P1C2C-49 | Drive Motor "B" Control Module AD Converter Circuit Internal Electronic Failure | Motor generator control ECU internal malfunction (1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning: Comes on |
| P1C63-1F | Drive Motor "B" Control Module Offset Power Circuit Intermittent | Motor generator control ECU internal malfunction detected when DTC P0C79-17, P0D33-19, P1C5D-19, P1C5F-19 or P1C5E-19 is stored. (1 trip detection logic) |
Inverter with converter assembly | Does not come on | Master Warning: Does not come on |
| P262C-1C | Drive Motor "B" Control Module Offset Power Circuit Voltage Out of Range | Motor generator control ECU internal malfunction (1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning: Comes on |
| P310B-1F | Communication Error from Drive Motor "A" to Drive Motor "B" Circuit Intermittent | Communication error (circuit intermittent from motor to rear motor) detected when DTC P0C79-17, P0D33-19, P1C5D-19, P1C5F-19 or P1C5E-19 is stored. (1 trip detection logic) |
Inverter with converter assembly | Does not come on | Master Warning: Does not come on |
| P310B-83 | Communication Error from Drive Motor "A" to Drive Motor "B" Value of Signal Protection Calculation Incorrect | Motor generator control ECU internal malfunction (1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning: Comes on |
| P310B-86 | Communication Error from Drive Motor "A" to Drive Motor "B" Signal (Some Circuit Quantity, Reported via Serial Data) Invalid | Motor generator control ECU internal malfunction (1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning: Comes on |
| P310B-87 | Communication Error from Drive Motor "A" to Drive Motor "B" Missing Message | Motor generator control ECU internal malfunction (1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning: Comes on |
| P32CF-1F | Lost Communication between Drive Motor "A" and "B" (Drive Motor "B") Circuit Intermittent | Communication error (circuit intermittent from generator to rear motor) detected when DTC P0C79-17, P0D33-19, P1C5D-19, P1C5F-19 or P1C5E-19 is stored. (1 trip detection logic) |
Inverter with converter assembly | Does not come on | Master Warning: Does not come on |
| P32CF-83 | Lost Communication between Drive Motor "A" and "B" (Drive Motor "B") Value of Signal Protection Calculation Incorrect | Motor generator control ECU internal malfunction (1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning: Comes on |
| P32CF-86 | Lost Communication between Drive Motor "A" and "B" (Drive Motor "B") Signal (Some Circuit Quantity, Reported via Serial Data) Invalid | Motor generator control ECU internal malfunction (1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning: Comes on |
| P32CF-87 | Lost Communication between Drive Motor "A" and "B" (Drive Motor "B") Missing Message | Motor generator control ECU internal malfunction (1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning: Comes on |