DTC P0C64-16: Generator Position Sensor Circuit "A" Circuit Voltage Below Threshold; DTC P0C64-17: Generator Position Sensor Circuit "A" Circuit Voltage Above Threshold; DTC P0C69-16: Generator Position Sensor Circuit "B" Circuit Voltage Below Threshold; DTC P0C69-17: Generator Position Sensor Circuit "B" Circuit Voltage Above Threshold [12/2019 - 11/2023]: Description
WARNING: This page is about a different variant/trim than selected.
Refer to the system description for the Generator Resolver Circuit.
Refer to SYSTEM DESCRIPTION
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
| P0C64-16 | Generator Position Sensor Circuit "A" Circuit Voltage Below Threshold | The value of the generator resolver sin phase signal is lower than the low side threshold. (1 trip detection logic) |
|
Comes on | Master Warning: Comes on |
| P0C64-17 | Generator Position Sensor Circuit "A" Circuit Voltage Above Threshold | The value of the generator resolver sin phase signal is higher than the high side threshold. (1 trip detection logic) |
|
Comes on | Master Warning: Comes on |
| P0C69-16 | Generator Position Sensor Circuit "B" Circuit Voltage Below Threshold | The value of the generator resolver cos phase signal is lower than the low side threshold. (1 trip detection logic) |
|
Comes on | Master Warning: Comes on |
| P0C69-17 | Generator Position Sensor Circuit "B" Circuit Voltage Above Threshold | The value of the generator resolver cos phase signal is higher than the high side threshold. (1 trip detection logic) |
|
Comes on | Master Warning: Comes on |