DTC P0E00-12: Generator Phase U Current Sensor Circuit Short to Battery; DTC P0E00-14: Generator Phase U Current Sensor Circuit Short to Ground or Open; DTC P0E00-1F: Generator Phase U Current Sensor Circuit Intermittent; DTC P0E04-12: Generator Phase V Current Sensor Circuit Short to Battery; DTC P0E04-14: Generator Phase V Current Sensor Circuit Short to Ground or Open; DTC P0E04-1F: Generator Phase V Current Sensor Circuit Intermittent; DTC P0E08-12: Generator Phase W Current Sensor Circuit Short to Battery; DTC P0E08-14: Generator Phase W Current Sensor Circuit Short to Ground or Open; DTC P0E08-1F: Generator Phase W Current Sensor Circuit Intermittent [12/2019 - 11/2023]: Description
WARNING: This page is about a different variant/trim than selected.
The motor generator control ECU (MG ECU), which is built into the inverter with converter assembly, monitors the generator inverter current sensor. These DTCs indicate the malfunction of current sensors and do not indicate a malfunction of the high-voltage system.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
| P0E00-12 | Generator Phase U Current Sensor Circuit Short to Battery | Malfunction in generator inverter current sensor (phase U main sensor) (Short to +B) (1 trip detection logic) |
|
Comes on | Master Warning: Comes on |
| P0E00-14 | Generator Phase U Current Sensor Circuit Short to Ground or Open | Malfunction in generator inverter current sensor (phase U main sensor) (Open or short to ground) (1 trip detection logic) |
|
Comes on | Master Warning: Comes on |
| P0E00-1F | Generator Phase U Current Sensor Circuit Intermittent | Short to +B, open or short to ground detected in generator inverter current sensor (phase U main sensor) when DTC P0C79-17, P0D33-19, P1C5D-19, P1C5F-19 or P1C5E-19 is stored. (1 trip detection logic) |
|
Does not come on | Master Warning: Does not come on |
| P0E04-12 | Generator Phase V Current Sensor Circuit Short to Battery | Malfunction in generator inverter current sensor (phase V main sensor) (Short to +B) (1 trip detection logic) |
|
Comes on | Master Warning: Comes on |
| P0E04-14 | Generator Phase V Current Sensor Circuit Short to Ground or Open | Malfunction in generator inverter current sensor (phase V main sensor) (Open or short to ground) (1 trip detection logic) |
|
Comes on | Master Warning: Comes on |
| P0E04-1F | Generator Phase V Current Sensor Circuit Intermittent | Short to +B, open or short to ground detected in generator inverter current sensor (phase V main sensor) when DTC P0C79-17, P0D33-19, P1C5D-19, P1C5F-19 or P1C5E-19 is stored. (1 trip detection logic) |
|
Does not come on | Master Warning: Does not come on |
| P0E08-12 | Generator Phase W Current Sensor Circuit Short to Battery | Malfunction in generator inverter current sensor (phase W main sensor) (Short to +B) (1 trip detection logic) |
|
Comes on | Master Warning: Comes on |
| P0E08-14 | Generator Phase W Current Sensor Circuit Short to Ground or Open | Malfunction in generator inverter current sensor (phase W main sensor) (Open or short to ground) (1 trip detection logic) |
|
Comes on | Master Warning: Comes on |
| P0E08-1F | Generator Phase W Current Sensor Circuit Intermittent | Short to +B, open or short to ground detected in generator inverter current sensor (phase W main sensor) when DTC P0C79-17, P0D33-19, P1C5D-19, P1C5F-19 or P1C5E-19 is stored. (1 trip detection logic) |
|
Does not come on | Master Warning: Does not come on |