Home >> Toyota >> 2021 >> Highlander LE, 4WD >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 73 (Motor Generator Control System (AWD) - Diagnostic Codes (4 Of 5)) >> MOTOR GENERATOR CONTROL SYSTEM (for AWD) >> DTC P0E00-28: Generator Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure; DTC P0E04-28: Generator Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure; DTC P0E08-28: Generator Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure [12/2019 - 11/2023] >> DTC Summary

DTC Summary

WARNING: This page is about a different variant/trim than selected.
  1. MALFUNCTION DESCRIPTION 

    These DTCs indicate that the current sensor value is abnormal. The cause of this malfunction may be one of the following:

    Internal inverter malfunction 

    • Current sensor malfunction
    • Inverter with converter assembly internal circuit malfunction