DTC Summary
WARNING: This page is about a different variant/trim than selected.
- MALFUNCTION DESCRIPTIONÂ
This DTC indicates that the motor torque execution value does not correspond to the torque command value sent from the hybrid vehicle control ECU to the motor (MG2). The cause of this malfunction may be one of the following:
Area Main Malfunction Description Inside of inverter Inverter with converter assembly internal circuit malfunction Hybrid vehicle transaxle assembly - Motor (MG2) internal malfunction (entry of foreign matter, etc.)
- Open or short circuit in the motor coils
Motor cable (for MG2) - Open circuit or poor insulation on motor cable (for MG2)
- Defective motor cable (for MG2) connection
Inverter low-voltage circuit The connectors are not connected properly Hybrid vehicle control ECU Hybrid vehicle control ECU internal circuit malfunction