DSD Information System
Home >> Toyota >> 2021 >> Highlander LE, 4WD >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 78 (Motor Generator Control System (AWD) - Diagnostic Codes (1 Of 5)) >> MOTOR GENERATOR CONTROL SYSTEM (for AWD) >> DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P06D6-1C: Generator Control Module Offset Power Circuit Voltage Out of Range; DTC P0A1A-47: Generator Control Module Watchdog / Safety MC Failure; DTC P0A1A-49: Generator Control Module Internal Electronic Failure; DTC P0A1C-47: Drive Motor "B" Control Module Watchdog / Safety MCU Failure; DTC P0A1C-49: Drive Motor "B" Control Module Internal Electronic Failure; DTC P1C2A-1C: Generator A/D Converter Circuit Circuit Voltage Out of Range; DTC P1C2A-49: Generator A/D Converter Circuit Internal Electronic Failure; DTC P1C2B-1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B-49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C2C-1C: Drive Motor "B" Control Module AD Converter Circuit Voltage Out of Range; DTC P1C2C-49: Drive Motor "B" Control Module AD Converter Circuit Internal Electronic Failure; DTC P1C60-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C62-1F: Generator Control Module Offset Power Circuit Intermittent; DTC P262C-1C: Drive Motor "B" Control Module Offset Power Circuit Voltage Out of Range; DTC P310A-1F: Communication Error from Drive Motor "B" to Drive Motor "A" Circuit Intermittent; DTC P310A-83: Communication Error from Drive Motor "B" to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P310A-86: Communication Error from Drive Motor "B" to Drive Motor "A" Signal (Some Circuit Quantity, Reported via Serial Data) Invalid; DTC P310A-87: Communication Error from Drive Motor "B" to Drive Motor "A" Missing Message; DTC P310B-83: Communication Error from Drive Motor "A" to Drive Motor "B" Value of Signal Protection Calculation Incorrect; DTC P310B-86: Communication Error from Drive Motor "A" to Drive Motor "B" Signal (Some Circuit Quantity, Reported via Serial Data) Invalid; DTC P310B-87: Communication Error from Drive Motor "A" to Drive Motor "B" Missing Message; DTC P3133-83: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P3133-86: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P3133-87: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P3134-83: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P3134-86: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P3134-87: Communication Error from Drive Motor "A" to Generator Missing Message; DTC P32BF-1F: Lost Communication between Drive Motor "A" and "B" (Drive Motor "A") Circuit Intermittent; DTC P32BF-83: Lost Communication between Drive Motor "A" and "B" (Drive Motor "A") Value of Signal Protection Calculation Incorrect; DTC P32BF-86: Lost Communication between Drive Motor "A" and "B" (Drive Motor "A") Signal (Some Circuit Quantity, Reported via Serial Data) Invalid; DTC P32BF-87: Lost Communication between Drive Motor "A" and "B" (Drive Motor "A") Missing Message; DTC P32CF-83: Lost Communication between Drive Motor "A" and "B" (Drive Motor "B") Value of Signal Protection Calculation Incorrect; DTC P32CF-86: Lost Communication between Drive Motor "A" and "B" (Drive Motor "B") Signal (Some Circuit Quantity, Reported via Serial Data) Invalid; DTC P32CF-87: Lost Communication between Drive Motor "A" and "B" (Drive Motor "B") Missing Message [12/2019 - 11/2023] >> Monitor Description

Monitor Description

WARNING: This page is about a different variant/trim than selected.

The motor generator control ECU monitors its internal operation and will illuminate the MIL and store a DTC if it detects a malfunction.