DSD Information System
Home >> Toyota >> 2021 >> Highlander LE, 4WD >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 109 (Hybrid Control System (AWD) - Diagnostic Codes (5 Of 6)) >> HYBRID CONTROL SYSTEM (for AWD) >> DTC P1C6A-9F: Motor Shutdown Stuck Off [12/2019 - 11/2023] >> Description

DTC P1C6A-9F: Motor Shutdown Stuck Off [12/2019 - 11/2023]: Description

WARNING: This page is about a different variant/trim than selected.

The motor generator control ECU (MG ECU) sends shutdown signals to the inverter to cut the power supply to the generator (MG1) and motor (MG2). If the ignition switch is turned off, the motor generator control ECU (MG ECU) will send a GSDN (MG1 Shutdown Signal) signal and MSDN (MG2 shutdown signal) signal to check the function of the HV gate block. If a shutdown malfunction is detected, this DTC will be stored.

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate
P1C6A-9F Motor Shutdown Stuck Off When the HV gate block function check is performed (when the ignition switch is turned from ON (READY) to off), the MSDN (MG2 shutdown) signal is sent but the motor (MG2) inverter current and voltage (VH) do not decrease.
(1 trip detection logic)
Inverter with converter assembly Does not come on Master Warning:
Comes on
RELATED DATA LIST

DTC No. Data List
P1C6A-9F
  • Ready Signal
  • VH-Voltage after Boosting