DTC P1C81-49: High Voltage Power Resource Circuit Consumption Circuit Short; DTC P1C82-49: High Voltage Power Resource Circuit Over Loading [12/2019 - 11/2023]: Description
WARNING: This page is about a different variant/trim than selected.
Refer to the description for DTC P0AE4-11.
Refer to DESCRIPTION
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
| P1C81-49 | High Voltage Power Resource Circuit Consumption Circuit Short | High-voltage circuit malfunctions between the HV battery and inverter with converter assembly. Excessive overcurrent equal to a short occurs during precharge (time from when SMRP turns on until SMRG turns on). (1 trip detection logic) |
|
Does not come on | Master Warning: Comes on |
| P1C82-49 | High Voltage Power Resource Circuit Over Loading | High-voltage circuit malfunctions between the HV battery and inverter with converter assembly. Small battery overcurrent occurs during precharge (time from when SMRP turns on until SMRG turns on) and current continues to flow after precharge. (1 trip detection logic) |
|
Does not come on | Master Warning: Comes on |
- *: w/ 1500W voltage inverter
RELATED DATA LIST
| DTC No. | Data List |
|---|---|
| P1C81-49 |
|