DTC P0ABF-2A: Hybrid/EV Battery Current Sensor "A" Signal Stuck In Range [12/2019 - 11/2023]: Procedure
- CHECK DTC OUTPUT (HYBRID CONTROL)
- Check and record any HV system DTCs and Freeze Frame Data.
Powertrain > Hybrid Control > Trouble Codes
Result
Result Proceed to "Only DTC P0ABF-2A is output" or "DTC P0ABF-2A and DTCs other than those in the following table are output". A DTC P0ABF-2A and any of the DTCs in the following table are output at the same time. B Relevant DTC P0A95-63 High Voltage Fuse Accumulated Load History P0ABF-11 Hybrid/EV Battery Current Sensor "A" Circuit Short to Ground P0ABF-15 Hybrid/EV Battery Current Sensor "A" Circuit Short to Auxiliary Battery or Open P0AFC-00 Hybrid/EV Battery Sensor Module P0AFC-96 Hybrid/EV Battery Sensor Module Component Internal Failure P1CBB-12 Hybrid/EV Battery Current Sensor Power Supply Circuit Short to Auxiliary Battery P1CBB-14 Hybrid/EV Battery Current Sensor Power Supply Circuit Short to Ground or Open P308A-12 Hybrid/EV Battery Voltage Sensor All Circuit Short to Auxiliary Battery P0B3B-14, P0B40-14, P0B45-14, P0B4A-14, P0B4F-14, P0B54-14, P0B59-14, P0B5E-14, P0B63-14, P0B68-14, P0B6D-14, P0B72-14, P0B77-14 Hybrid/EV Battery Voltage Sensor "A - M" Circuit Short to Ground or Open - Turn the ignition switch off.
Result:
B
GO TO DTC CHART (HYBRID CONTROL SYSTEM). Refer to DIAGNOSTIC TROUBLE CODE CHART [12/2019 - 09/2020] , or refer to DIAGNOSTIC TROUBLE CODE CHART [09/2020 - 10/2021] , or refer to DIAGNOSTIC TROUBLE CODE CHART [10/2021 - 11/2023]
Result:
A
See step 2
- Check and record any HV system DTCs and Freeze Frame Data.
- READ VALUE USING GTS
- Turn the ignition switch to ON.NOTE:
Do not turn the ignition switch to ON (READY).
- Check the voltage of each HV battery block voltage of "Hybrid Battery Block 1 to 12 Voltage" in the Data List with the ignition switch ON.NOTE:
Select "Hybrid Battery Block 1 to 12 Voltage" only. (Do not select any other Data List items.)
Powertrain > Hybrid Control > Data List
Tester Display Hybrid Battery Block 1 Voltage Hybrid Battery Block 2 Voltage Hybrid Battery Block 3 Voltage Hybrid Battery Block 4 Voltage Hybrid Battery Block 5 Voltage Hybrid Battery Block 6 Voltage Hybrid Battery Block 7 Voltage Hybrid Battery Block 8 Voltage Hybrid Battery Block 9 Voltage Hybrid Battery Block 10 Voltage Hybrid Battery Block 11 Voltage Hybrid Battery Block 12 Voltage Specified Condition
Any "Hybrid Battery Block Voltage" changes by 0.3 V or more, 60 seconds after the ignition switch is turned to ON. (The difference between the maximum and minimum voltage is 0.3 V or more.)
Result
Result Proceed to The change in voltage of any "Hybrid Battery Block Voltage" is 0.3 V or more. A Other than above B - Turn the ignition switch off.
Result:
A
REPLACE BATTERY VOLTAGE SENSOR. Refer to REMOVAL [12/2019 - 10/2022] , or refer to REMOVAL [10/2022 - 11/2023]
Result:
B
REPLACE HV BATTERY JUNCTION BLOCK ASSEMBLY. Refer to REMOVAL [12/2019 - 10/2022] , or refer to REMOVAL [10/2022 - 11/2023]
- Turn the ignition switch to ON.