DTC P0B3B-14: Hybrid/EV Battery Voltage Sensor "A" Circuit Short to Ground or Open; DTC P0B40-14: Hybrid/EV Battery Voltage Sensor "B" Circuit Short to Ground or Open; DTC P0B45-14: Hybrid/EV Battery Voltage Sensor "C" Circuit Short to Ground or Open; DTC P0B4A-14: Hybrid/EV Battery Voltage Sensor "D" Circuit Short to Ground or Open; DTC P0B4F-14: Hybrid/EV Battery Voltage Sensor "E" Circuit Short to Ground or Open; DTC P0B54-14: Hybrid/EV Battery Voltage Sensor "F" Circuit Short to Ground or Open; DTC P0B59-14: Hybrid/EV Battery Voltage Sensor "G" Circuit Short to Ground or Open; DTC P0B5E-14: Hybrid/EV Battery Voltage Sensor "H" Circuit Short to Ground or Open; DTC P0B63-14: Hybrid/EV Battery Voltage Sensor "I" Circuit Short to Ground or Open; DTC P0B68-14: Hybrid/EV Battery Voltage Sensor "J" Circuit Short to Ground or Open; DTC P0B6D-14: Hybrid/EV Battery Voltage Sensor "K" Circuit Short to Ground or Open; DTC P0B72-14: Hybrid/EV Battery Voltage Sensor "L" Circuit Short to Ground or Open; DTC P0B77-14: Hybrid/EV Battery Voltage Sensor "M" Circuit Short to Ground or Open; DTC P308A-13: Hybrid/EV Battery Voltage Sensor All Circuit Open [12/2019 - 11/2023]: Description
WARNING: This page is about a different variant/trim than selected.
Refer to the description for DTC P1AC0-00.
Refer to DESCRIPTION
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
| P0B3B-14 | Hybrid/EV Battery Voltage Sensor "A" Circuit Short to Ground or Open | The battery block voltage detection line has a malfunction and any of the battery block voltages become lower than the specified value (open). (1 trip detection logic) |
|
Comes on | Master Warning: Comes on |
| P0B40-14 | Hybrid/EV Battery Voltage Sensor "B" Circuit Short to Ground or Open | The battery block voltage detection line has a malfunction and any of the battery block voltages become lower than the specified value (open). (1 trip detection logic) |
|
Comes on | Master Warning: Comes on |
| P0B45-14 | Hybrid/EV Battery Voltage Sensor "C" Circuit Short to Ground or Open | The battery block voltage detection line has a malfunction and any of the battery block voltages become lower than the specified value (open). (1 trip detection logic) |
|
Comes on | Master Warning: Comes on |
| P0B4A-14 | Hybrid/EV Battery Voltage Sensor "D" Circuit Short to Ground or Open | The battery block voltage detection line has a malfunction and any of the battery block voltages become lower than the specified value (open). (1 trip detection logic) |
|
Comes on | Master Warning: Comes on |
| P0B4F-14 | Hybrid/EV Battery Voltage Sensor "E" Circuit Short to Ground or Open | The battery block voltage detection line has a malfunction and any of the battery block voltages become lower than the specified value (open). (1 trip detection logic) |
|
Comes on | Master Warning: Comes on |
| P0B54-14 | Hybrid/EV Battery Voltage Sensor "F" Circuit Short to Ground or Open | The battery block voltage detection line has a malfunction and any of the battery block voltages become lower than the specified value (open). (1 trip detection logic) |
|
Comes on | Master Warning: Comes on |
| P0B59-14 | Hybrid/EV Battery Voltage Sensor "G" Circuit Short to Ground or Open | The battery block voltage detection line has a malfunction and any of the battery block voltages become lower than the specified value (open). (1 trip detection logic) |
|
Comes on | Master Warning: Comes on |
| P0B5E-14 | Hybrid/EV Battery Voltage Sensor "H" Circuit Short to Ground or Open | The battery block voltage detection line has a malfunction and any of the battery block voltages become lower than the specified value (open). (1 trip detection logic) |
|
Comes on | Master Warning: Comes on |
| P0B63-14 | Hybrid/EV Battery Voltage Sensor "I" Circuit Short to Ground or Open | The battery block voltage detection line has a malfunction and any of the battery block voltages become lower than the specified value (open). (1 trip detection logic) |
|
Comes on | Master Warning: Comes on |
| P0B68-14 | Hybrid/EV Battery Voltage Sensor "J" Circuit Short to Ground or Open | The battery block voltage detection line has a malfunction and any of the battery block voltages become lower than the specified value (open). (1 trip detection logic) |
|
Comes on | Master Warning: Comes on |
| P0B6D-14 | Hybrid/EV Battery Voltage Sensor "K" Circuit Short to Ground or Open | The battery block voltage detection line has a malfunction and any of the battery block voltages become lower than the specified value (open). (1 trip detection logic) |
|
Comes on | Master Warning: Comes on |
| P0B72-14 | Hybrid/EV Battery Voltage Sensor "L" Circuit Short to Ground or Open | The battery block voltage detection line has a malfunction and any of the battery block voltages become lower than the specified value (open). (1 trip detection logic) |
|
Comes on | Master Warning: Comes on |
| P0B77-14 | Hybrid/EV Battery Voltage Sensor "M" Circuit Short to Ground or Open | The battery block voltage detection line has a malfunction and any of the battery block voltages become lower than the specified value (open). (1 trip detection logic) |
|
Comes on | Master Warning: Comes on |
| P308A-13 | Hybrid/EV Battery Voltage Sensor All Circuit Open | The battery block voltage detection line is open (all blocks) or all battery block voltages become lower than the specified value (possibility of open or loosely connected connector). (1 trip detection logic) |
|
Comes on | Master Warning: Comes on |
HINT:
Hybrid Battery Block 1 to 12 Voltage values smaller than 2.0 V may not be shown in the Data List because a fail-safe value is substituted.
RELATED DATA LIST
| DTC No. | Data List |
|---|---|
| P0B3B-14 | Hybrid Battery Block 1 to 12 Voltage*1 |
| P0B40-14 | |
| P0B45-14 | |
| P0B4A-14 | |
| P0B4F-14 | |
| P0B54-14 | |
| P0B59-14 | |
| P0B5E-14 | |
| P0B63-14 | |
| P0B68-14 | |
| P0B6D-14 | |
| P0B72-14 | |
| P0B77-14 | |
| P308A-13 |
|
HINT:
- *1: Under normal conditions, the values of Hybrid Battery Block 1, 2, 11 and 12 Voltage will be approximately 16 V and Hybrid Battery Block 3, 4, 5, 6, 7, 8, 9 and 10 Voltage will be approximately 32 V.
- If there is a short or open in a battery block voltage detection line, the value of Hybrid Battery Block Voltage for the corresponding battery block will be lower than 8 V.