Illumination Circuit [12/2019 - 10/2022]: Procedure
- CHECK METER / GAUGE SYSTEM
- Check if the rheostat function operates normally.
OK
The rheostat function operates normally.
Result
Proceed to OK NG
Result:
NG
GO TO METER / GAUGE SYSTEM. Refer to HOW TO PROCEED WITH TROUBLESHOOTING [12/2019 - ]
Result:
OK
See step 2
- Check if the rheostat function operates normally.
- CHECK LIGHTING SYSTEM (INT)
- Check if the instrument panel illumination comes on normally.
OK
The instrument panel illumination comes on normally.
Result
Proceed to OK NG
Result:
NG
GO TO LIGHTING SYSTEM (INT). Refer to HOW TO PROCEED WITH TROUBLESHOOTING [12/2019 - 11/2023]
Result:
OK
See step 3
- Check if the instrument panel illumination comes on normally.
- CHECK HARNESS AND CONNECTOR (ILLUMINATION SIGNAL CIRCUIT)
- Disconnect the R16 television display assembly connector.
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Switch Condition Specified Condition R16-15 (ILL+) - Body ground Ignition switch off
Light control switch in tail or head position11 to 14 V - Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition R16-16 (ILL-) - Body ground Always Below 1 Ω Result
Proceed to OK NG
Result:
OK
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE. Refer to PROBLEM SYMPTOMS TABLE [12/2019 - 10/2022]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR