Inspection [12/2019 - ]: Procedure
WARNING: This page is about a different variant/trim than selected.
- INSPECT HV BATTERY JUNCTION BLOCK ASSEMBLY
- Inspect SMRB:
- Measure the resistance according to the value(s) in the table below.
*a Component without harness connected
(HV Battery Junction Block Assembly)- - Standard Resistance
Tester Connection Condition Specified Condition z11-1 (+) - k2-1 (CBI) Auxiliary battery voltage not applied between terminals M56-1 (SMRB) and M56-3 (GND) 10 kΩ or higher Auxiliary battery voltage applied between terminals M56-1 (SMRB) and M56-3 (GND) Below 1 Ω - Measure the resistance according to the value(s) in the table below.
Standard Resistance
Denso Made
Tester Connection Condition Specified Condition M56-1 (SMRB) - M56-3 (GND) -40 to 80°C (-40 to 176°F) 25.0 to 59.0 Ω Panasonic Made
Tester Connection Condition Specified Condition M56-1 (SMRB) - M56-3 (GND) -40 to 80°C (-40 to 176°F) 20.6 to 40.8 Ω If the result is not as specified, replace the HV battery junction block assembly.
- Measure the resistance according to the value(s) in the table below.
- Inspect SMRG:
- Measure the resistance according to the value(s) in the table below.
*a Component without harness connected
(HV Battery Junction Block Assembly)- - Standard Resistance
Tester Connection Condition Specified Condition z9-1 (-) - k3-1 (CEI) Auxiliary battery voltage not applied between terminals M56-4 (SMRG) and M56-3 (GND) 10 kΩ or higher Auxiliary battery voltage applied between terminals M56-4 (SMRG) and M56-3 (GND) Below 1 Ω - Measure the resistance according to the value(s) in the table below.
Standard Resistance
Denso Made
Tester Connection Condition Specified Condition M56-4 (SMRG) - M56-3 (GND) -40 to 80°C (-40 to 176°F) 25.0 to 59.0 Ω Panasonic Made
Tester Connection Condition Specified Condition M56-4 (SMRG) - M56-3 (GND) -40 to 80°C (-40 to 176°F) 20.6 to 40.8 Ω If the result is not as specified, replace the HV battery junction block assembly.
- Measure the resistance according to the value(s) in the table below.
- Inspect SMRP:
- Measure the resistance according to the value(s) in the table below.
*a Component without harness connected
(HV Battery Junction Block Assembly)- - Standard Resistance
Tester Connection Condition Specified Condition z9-1 (-) - k3-1 (CEI) Auxiliary battery voltage not applied between terminals M56-2 (SMRP) and M56-3 (GND) 10 kΩ or higher Auxiliary battery voltage applied between terminals M56-2 (SMRP) and M56-3 (GND) 24.3 to 29.7 Ω - Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition M56-2 (SMRP) - M56-3 (GND) -40 to 80°C (-40 to 176°F) 140 to 290 Ω If the result is not as specified, replace the HV battery junction block assembly.
- Measure the resistance according to the value(s) in the table below.
- Inspect SMRB: